PRODUCT SKU : 2711-T10G8

PRODUCT TYPE : Standard Operator Terminal

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 2711-T10G8 functions as a ruggedized Human-Machine Interface (HMI) for the PanelView 1000 Standard series. It provides high-performance visualization and control for PLC-5 and SLC 500 systems via the Data Highway Plus (DH+) network. This unit features a 10.1-inch grayscale TFT display and a resistive touchscreen for seamless operator interaction. We supply this terminal as 100% Brand New, original factory stock, ensuring the highest reliability for legacy control system maintenance and critical infrastructure support.

Technical Specifications

The 2711-T10G8 integrates a wide-range power supply with high-density touch cells for precise machine command.

Feature Specification
Manufacturer Allen Bradley (Rockwell Automation)
Display Size 10.1-inch (211 x 158 mm active area)
Display Type Grayscale TFT (4 shades of gray)
Resolution 640 x 480 pixels
Input Type Analog Resistive Touchscreen (384 touch cells)
Communication Data Highway Plus (DH+); RS-232 (Printer)
Application Memory 1008 KB Non-volatile (Flash)
Input Voltage 85–264V AC (47–63 Hz)
Backlight Life 100,000 Hours
Enclosure Rating NEMA Type 12/13, 4X (Indoor Use)
Weight 6.00 lbs (2.72 kg)

Engineering Advantages

  • Optimized Legacy Connectivity: The integrated DH+ port facilitates direct connection to existing industrial networks without requiring external protocol converters. This ensures high-speed data synchronization with PLC-5, SLC 5/04, and ControlLogix (via DH+ modules) controllers.

  • Universal Power Compatibility: The internal power supply accepts a wide input range from 85V to 264V AC. This allows the terminal to operate in diverse electrical environments globally without the need for additional isolation transformers or voltage step-down units.

  • Superior Environmental Sealing: This HMI achieves NEMA 4X (Indoor) and NEMA 12/13 ratings when properly panel-mounted. The enclosure prevents the ingress of dust, oil, and non-corrosive liquids, protecting the internal electronics in harsh machining and assembly environments.

  • Long-Life Illumination: The backlight assembly provides up to 100,000 hours of service. This significantly reduces maintenance intervals and total cost of ownership (TCO) compared to standard consumer-grade displays that often fail under 24/7 industrial duty cycles.

FAQs

  • Can I use the 2711-T10G8 to replace a keypad-style PanelView?

    The 2711-T10G8 uses a touchscreen interface. If your existing application utilizes a keypad-only model (e.g., 2711-K10G8), you must modify the panel cutout and reconfigure the application software in PanelBuilder32 to accommodate the touch-based navigation.

  • Does this unit support direct connection to a computer for programming?

    The DH+ port manages network traffic, while the RS-232 port primarily handles printer output. For programming and application transfer, we recommend using a 1747-UIC or a similar interface if your PC lacks a native DH+ card (like the 1784-U2DHP).

  • What is the significance of the "G8" in the part number?

    The "G" signifies a Grayscale display (4 shades), and the "8" identifies the communication protocol as Data Highway Plus (DH+). This specific combination targets cost-effective yet high-speed network visualization where full color is not required for process safety.

  • What mounting precautions should I take for NEMA 4X compliance?

    Ensure the panel cutout precisely matches the manufacturer’s specifications. You must use the included mounting clips and tighten them to the specified torque to create a uniform seal against the gasket, which prevents moisture and contaminants from entering the cabinet.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering PLC Programming: Best Practices for Robust Industrial Automation

Mastering PLC Programming: Best Practices for Robust Industrial Automation

Writing clean PLC code requires discipline, especially regarding memory management. Avoid overusing SET and RESET instructions, as they often complicate debugging. If multiple rungs control the same bit, troubleshooting becomes a nightmare. Instead, focus on energizing a bit in only one location. If your logic requires complex conditions, use branches within a single rung. This approach keeps your code readable, maintainable, and significantly easier to audit during downtime.

Read more
PLC vs. HMI: Distinguishing the Brain from the Interface in Industrial Automation

PLC vs. HMI: Distinguishing the Brain from the Interface in Industrial Automation

In the realm of industrial automation, distinguishing between a Programmable Logic Controller (PLC) and a Human-Machine Interface (HMI) is fundamental. While both devices work in tandem, they serve distinct purposes. The PLC acts as the "brain" of the operation, executing logic, whereas the HMI serves as the "eyes," allowing operators to monitor and interact with the system. Understanding this synergy is essential for any professional designing robust factory automation solutions.

Read more
Selecting the Right Industrial Automation Solution for Modern Manufacturing

Selecting the Right Industrial Automation Solution for Modern Manufacturing

Choosing an effective industrial automation system starts with a thorough process audit. You must identify tasks that are repetitive, labor-intensive, or prone to human error. Not every process requires high-level automation; therefore, prioritize operations that directly impact throughput and quality. By scoping your needs accurately, you avoid over-investing in unnecessary technology. A balanced approach ensures that your capital expenditure aligns with measurable gains in operational efficiency.

Read more