PRODUCT SKU : 1769-OF8C

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1769-OF8C is an 8-channel compact analog output module for CompactLogix systems. It delivers precise current signals with high reliability and protection features suitable for industrial control applications.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Series / Product Line: CompactLogix

  • Model / Part Number: 1769-OF8C

  • Module Type: 8-Point Analog Current Output Module

  • Outputs: 8 single-ended

  • Output Current Ranges: 0–20 mA, 4–20 mA

  • Full Scale Range: 0–21 mA, 3.2–21 mA

  • Resolution: 16-bit unipolar; 15.59–15.91 bits depending on range

  • Bus Current Draw: 5 VDC @ 145 mA, 24 VDC @ 185 mA

  • Maximum Heat Dissipation: 2.69 W

  • Conversion Rate (All Channels): 5 ms

  • Step Response: < 2.9 ms

  • Load Resistance: Resistive 0–500 Ω, Inductive max 0.1 mH

  • Accuracy: ±0.35% full scale @ 25°C; temperature drift ±0.0058% per °C

  • Output Ripple: ±0.05% @ 0–50 kHz

  • Nonlinearity: ±0.05%

  • Repeatability: ±0.05%

  • Module Error / Offset Error: ±0.55%

  • Open / Short-Circuit Protection: Yes, max 21 mA short-circuit

  • Overvoltage Protection: Yes

  • Rated Working Voltage: 30 V AC / 30 V DC

  • Isolation Voltage: 500 V AC / 710 V DC for 1 min, output to bus

  • Weight: 0.60 lb (270 g)

  • Dimensions: 118 x 35 x 87 mm (H x W x D), height with mounting tabs 138 mm

  • Slot Width: 1

  • Mounting: DIN rail or panel mount

  • Compatible Power Supplies: 1769-PA2, 1769-PB2, 1769-PA4, 1769-PB4

  • Optional 24V DC Class 2 Supply Voltage Range: 20.4–26.4 VDC

  • Power Supply Distance Rating: Up to 8 modules

  • Terminal / Retaining Screw Torque: 0.68 N·m / 0.46 N·m

  • Wire Size: Solid 22–14 AWG, Stranded 22–16 AWG, Cu-90°C

  • Replacement Accessories: Terminal Block 1769-RTBN18, Door Label 1769-RL2, Door 1769-RD

Key Features

  • 8 high-precision analog outputs with multiple current ranges

  • Full protection: open/short circuit, overvoltage, and transient suppression

  • High-resolution output with minimal ripple and low drift

  • Compact size, suitable for DIN rail or panel mounting

  • Compatible with multiple CompactLogix power supplies and configurations

Application Scenarios

The 1769-OF8C is ideal for:

  • Driving field devices with analog current outputs, such as valves, actuators, and transducers

  • High-accuracy process control applications requiring stable outputs

  • Compact control cabinets with limited space for I/O modules

Similar Model Comparison

  • 1769-OF8C – 8-channel analog current output, high-density

  • 1769-OF4C – 4-channel analog output, smaller footprint

  • 1769-OF16 – 16-channel analog output module for larger systems

FAQs

Q: Does the module require field calibration?
A: No field calibration is required; outputs are factory calibrated.

Q: What protection features are included?
A: Open/short-circuit, overvoltage, and spike suppression.

Q: Which power supplies are compatible?
A: 1769-PA2, 1769-PB2, 1769-PA4, 1769-PB4 with up to 8 modules per supply.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more
Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Industrial automation relies on continuous operational stability to prevent catastrophic downtime and financial loss. While standard dictionary definitions treat redundancy as superfluous, industrial engineers consider redundant control architectures indispensable for high-availability systems. Implementing backup hardware ensures seamless takeover during primary equipment failures, protecting critical infrastructure across manufacturing and process industries.

Read more