Allen-Bradley 1756-OB8EI ControlLogix 8-Point Electronically Fused Output Module
Allen-Bradley 1756-OB8EI ControlLogix 8-Point Electronically Fused Output Module
Allen-Bradley 1756-OB8EI ControlLogix 8-Point Electronically Fused Output Module

Allen-Bradley 1756-OB8EI ControlLogix 8-Point Electronically Fused Output Module


Only 10 left - Selling fast

PRODUCT SKU : 1756-OB8EI

PRODUCT TYPE : Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen-Bradley 1756-OB8EI functions as a high-reliability digital output interface within the ControlLogix platform. This module provides eight independent, isolated output channels designed to switch DC loads. The "EI" designation indicates Electronic Fusing and Individually Isolated channels, offering superior protection and diagnostic capabilities compared to standard output cards. We supply this unit as 100% Brand New original factory stock, ensuring your mission-critical control loops benefit from advanced fault detection and circuit isolation.

Technical Specifications

Feature Specification
Manufacturer Allen-Bradley / Rockwell Automation
Product Line ControlLogix (1756)
Number of Outputs 8 Individually Isolated Channels
Voltage Category 12/24V DC Sourcing
Operating Voltage Range 10–30V DC
Output Current Rating 2.0A per point @ 30°C / 1.0A per point @ 60°C
Surge Current 4.0A for 10 ms, repeatable every 2 s
Isolation Voltage 250V (Continuous)
Fusing Type Electronic, Individual per channel
Backplane Current 250 mA @ 5.1V DC; 10 mA @ 24V DC
Power Dissipation 4.3 Watts (Max)

Engineering Advantages

  • Advanced Electronic Fusing: The 1756-OB8EI incorporates smart electronic fusing that detects overcurrent or short-circuit conditions on a per-channel basis. This hardware feature eliminates the need for physical glass fuses and provides an automatic reset capability once the fault clears, significantly reducing downtime.

  • Point-to-Point Isolation: Each of the eight channels operates with total electrical isolation from the others (250V continuous). This prevents a single field-side fault or ground loop from propagating across the entire module, ensuring that a localized failure does not compromise the remaining seven control circuits.

  • Real-Time Diagnostic Feedback: The module communicates "Fused-Out" and "Field Power Loss" status directly to the ControlLogix processor. Maintenance teams can view these diagnostics via Studio 5000 or an HMI, enabling rapid identification of the exact failed field device without manual testing.

  • High-Current Drive Capability: Supporting up to 2.0A per point at 30°C, this module directly drives larger DC solenoid valves, motor starters, and signaling devices that typically require interposing relays when used with standard 0.5A output cards.

  • Configurable States: Engineers can program the "Fault State" for each output (Hold Last State, On, or Off). This allows for a customized "Fail-Safe" strategy, ensuring the process enters a controlled, safe condition during a communication loss or controller fault.

FAQs

  • Does the 1756-OB8EI require a specific Removable Terminal Block (RTB)?

    Yes. This module requires the 36-pin 1756-TBNH or 1756-TBSH RTB. Note that the terminal block is sold separately and must be wired according to the isolated channel layout.

  • Can I use this module to switch AC loads?

    No. The 1756-OB8EI is strictly a DC sourcing module. Attempting to switch AC voltage will damage the internal power transistors and void the warranty. For AC applications, utilize a 1756-OA8 or 1756-OW16I.

  • What happens when the electronic fuse trips?

    The module turns off the affected output and sends a diagnostic bit to the PLC. The "I/O" status LED on the front of the module will indicate a fault. Once you remove the short circuit, the fuse resets based on the module configuration in the software.

  • How do I verify this is a 100% Brand New unit?

    Every 1756-OB8EI we ship arrives in its Original Factory Packaging with intact seals. As a brand-new unit, the gold backplane connectors will show no insertion marks, and the internal diagnostic logs will be clear, guaranteeing full service life.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Signal Cables vs. Control Cables: Navigating Industrial Wiring Standards

Signal Cables vs. Control Cables: Navigating Industrial Wiring Standards

In the complex ecosystem of industrial automation, selecting the correct cabling is as vital as choosing the right PLC. While both signal and control cables facilitate communication within control systems, they serve distinct roles. Understanding these differences ensures signal integrity and prevents costly hardware damage on the factory floor.

Read more
Best Practices for Safety in PLC System Design and Industrial Automation

Best Practices for Safety in PLC System Design and Industrial Automation

Beyond programming, true engineering excellence in industrial automation requires a robust and safe hardware design. This guide explores essential safety considerations—from power supply stability to critical interlocks—ensuring your control system protects both personnel and high-value machinery effectively.

Read more
A Technical Guide to PLC Power Supply Standards and Operating Voltages

A Technical Guide to PLC Power Supply Standards and Operating Voltages

This guide explores standard operating voltages and power distribution strategies for modern control systems. Learn how to identify the correct power profile for your PLC to maintain logic integrity, prevent hardware failure, and ensure stable field communication in any industrial automation environment.

Read more