Skip to content

What are you looking for?


You may also like

Allen-Bradley 1756-IT6I 6-Channel Isolated TC Analog Input ModuleAllen-Bradley 1756-IT6I 6-Channel Isolated TC Analog Input ModuleAllen-Bradley 1756-IT6I 6-Channel Isolated TC Analog Input Module
Allen-Bradley 1756-IT6I 6-Channel Isolated TC Analog Input Module
Allen-Bradley 1756-IT6I 6-Channel Isolated TC Analog Input Module
Allen-Bradley 1756-IT6I 6-Channel Isolated TC Analog Input Module

Allen-Bradley 1756-IT6I 6-Channel Isolated TC Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1756-IT61

PRODUCT TYPE : Isolated Thermocouple Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1756-IT6I is a ControlLogix analog thermocouple input module featuring six isolated channels. It provides high-accuracy temperature measurement and flexible integration for industrial automation applications, supporting a wide range of thermocouple types.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: ControlLogix

  • Model / Part Number: 1756-IT6I

  • Product Type: 6-Point Isolated Thermocouple Input Module

  • Module Type: Analog Thermocouple Module (Isolated)

  • Number of Inputs: 6 isolated thermocouple channels + 1 CJC channel

  • Supported Thermocouples: B, C, E, J, K, N, R, S, T

  • Input Range: -12…78 mV (typical), -12…30 mV (high-resolution range)

  • Resolution: 16 bits, 0.7–1.4 µV/bit depending on input range

  • Data Format: Integer mode (left justified, 2’s complement), IEEE 32-bit floating point

  • Module Scan Time: 25 ms min floating point (millivolt), 50 ms min floating point (temperature), 10 ms min integer (millivolt)

  • Backplane Current: 5V DC: 250 mA, 24V DC: 125 mA

  • Power Dissipation: 4.3 W max

  • Removable Terminal Blocks: 1756-TBNH, 1756-TBSH

  • Enclosure Type: Open

  • Weight: 1.38 lbs (0.62 kg)

Key Features

  • Fully isolated inputs for accurate thermocouple measurement without cross-channel interference

  • Supports multiple thermocouple types for versatile process monitoring

  • High-resolution input for precision signal conversion

  • Compatible with ControlLogix chassis and removable terminal blocks for easy installation

  • Low power consumption and minimal heat generation

Application Scenarios

  • Industrial temperature monitoring and process automation requiring isolated thermocouple inputs

  • Integration with ControlLogix PLCs for precision process control

  • Multi-channel temperature acquisition for SCADA or HMI systems

  • Replacement or upgrade for existing 6-point TC modules in ControlLogix racks

FAQs

Q: How many thermocouple channels are isolated?
A: All six input channels are fully isolated for accurate measurements.

Q: Which thermocouple types are supported?
A: B, C, E, J, K, N, R, S, and T thermocouples are compatible.

Q: What is the module scan time?
A: Scan times range from 10 ms (integer millivolt) to 50 ms (floating point temperature) depending on configuration.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Variable Frequency Drives (VFDs) play a crucial role in modern industrial automation by controlling motor speed, torque, and acceleration. However, high-inertia loads and vertical lifting systems require precise mechanical braking logic to ensure operational safety and prevent equipment damage.

Read more
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more