Skip to content

What are you looking for?


You may also like

Allen-Bradley 1746-NI16I SLC 500 16-Channel Analog Input ModuleAllen-Bradley 1746-NI16I SLC 500 16-Channel Analog Input ModuleAllen-Bradley 1746-NI16I SLC 500 16-Channel Analog Input Module
Allen-Bradley 1746-NI16I SLC 500 16-Channel Analog Input Module
Allen-Bradley 1746-NI16I SLC 500 16-Channel Analog Input Module
Allen-Bradley 1746-NI16I SLC 500 16-Channel Analog Input Module

Allen-Bradley 1746-NI16I SLC 500 16-Channel Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1746-NI16I

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1746-NI16I is a 16-channel SLC 500 analog input module designed for precise signal acquisition in control systems. It supports multiple current input ranges, high-resolution sigma-delta conversion, and features robust isolation for reliable operation in industrial environments.

Technical Specifications

  • Manufacturer: Allen-Bradley (Rockwell Automation)

  • Model / Part Number: 1746-NI16I

  • Product Type: Analog Input Module

  • Product Line: SLC 500

  • Number of Inputs: 16 channels

  • Input Signal Types: 0–20 mA, 4–20 mA, ±20 mA, 0–1 mA

  • Bandwidth: 6–250 Hz

  • Step Response: 9–630 ms

  • Input Filtering: Low-pass digital filter with programmable frequencies (6, 10, 20, 40, 60, 80, 100, 250 Hz)

  • Conversion Type: Sigma-Delta

  • Backplane Current: 125 mA @ 5 VDC; 75 mA @ 24 VDC

  • Isolation: 500 V AC for 1 second (channel-to-backplane)

  • LED Indicators: 5 green LEDs (one per group of four channels) plus module status indicator

  • Chassis Location: Any I/O slot except slot 0

  • Thermal Dissipation: 2.43 W

  • Recommended Cabling: Belden #8761 or equivalent

Key Features

  • Supports multiple analog current ranges for flexible system integration

  • 16 individually monitored channels with group status indicators

  • Sigma-Delta A/D conversion for precise analog-to-digital performance

  • Digital low-pass filtering reduces signal noise

  • High isolation voltage ensures system reliability

Applications

  • Process monitoring and measurement in SLC 500 systems

  • Integration with 120V AC I/O and other analog devices

  • Industrial automation requiring high-accuracy analog signal inputs

FAQs

Q1: What input signal ranges does 1746-NI16I support?
It supports 0–20 mA, 4–20 mA, ±20 mA, and 0–1 mA signals.

Q2: How is channel status indicated?
Each group of four channels has a green LED, with an additional LED for module status.

Q3: What isolation does the module provide?
The module provides 500 V AC isolation for 1 second, protecting the backplane and input signals.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Dry Contacts in PLC Wiring: An Industrial Automation Guide

Understanding Dry Contacts in PLC Wiring: An Industrial Automation Guide

Mastering contact switching principles is essential for reliable control panels. Field devices and PLCs interface through dry or wet contacts. This technical guide examines the mechanics of dry contacts, explores their wiring architectures, and evaluates their key advantages in industrial automation.

Read more
Ultimate Commissioning Checklist for Industrial Automation Systems: An Engineering Guide

Ultimate Commissioning Checklist for Industrial Automation Systems: An Engineering Guide

Commissioning is the most decisive phase of an industrial automation project, transforming control hardware and software into an operational facility. Thorough testing prevents costly startup delays and builds customer confidence. This guide covers essential checklists, electrical standards, and best practices.

Read more
Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Unplanned downtime poses a major financial threat to process manufacturing. To prevent costly interruptions, engineers deploy redundant PLC and DCS architectures that ensure continuous operation when hardware fails. This technical guide explores redundancy principles, critical system nodes, and real-world scenarios.

Read more