PRODUCT SKU : 1734-0E2V

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen Bradley 1734-OE2V is a POINT I/O analog output module designed to provide two single-ended, non-isolated voltage outputs. Compact and lightweight, it integrates seamlessly into POINT I/O systems, offering fast conversion rates and high-resolution signal processing. With a signed integer data format and 14-bit resolution, the module ensures precise voltage control for industrial automation applications.

Technical Specifications

  • Manufacturer Allen Bradley

  • Product Line POINT I/O 1734 Series

  • Product Type Analog Output Module

  • Part Number 1734-OE2V

  • Weight 0.13 lbs (0.06 kg)

  • Outputs 2 single-ended, non-isolated analog voltage outputs

  • Output Voltage Range 0–10 V DC

  • Current Load 3 mA

  • Conversion Type Digital-to-Analog

  • Conversion Rate 20 µs

  • Data Format Signed integer

  • Resolution 14-bit

  • Operating Temperature –20 to 55 °C

Application Scenarios

  • Machine-level automation requiring precise voltage signal control

  • Distributed POINT I/O systems with compact analog output needs

  • Industrial environments needing fast conversion and high-resolution outputs

FAQ

Q: How many outputs does the 1734-OE2V provide?  A: It supports two single-ended, non-isolated voltage outputs.

Q: What is the resolution of the module?  A: The module offers 14-bit resolution for accurate signal processing.

Q: What is the conversion rate?  A: 20 microseconds per conversion.

Comparable Models

  • 1734-OE2V: 2-channel voltage output module (this model)

  • 1734-IE2V: 2-channel voltage input module

  • 1734-OE4V: 4-channel voltage output module

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering PLC Programming: Best Practices for Robust Industrial Automation

Mastering PLC Programming: Best Practices for Robust Industrial Automation

Writing clean PLC code requires discipline, especially regarding memory management. Avoid overusing SET and RESET instructions, as they often complicate debugging. If multiple rungs control the same bit, troubleshooting becomes a nightmare. Instead, focus on energizing a bit in only one location. If your logic requires complex conditions, use branches within a single rung. This approach keeps your code readable, maintainable, and significantly easier to audit during downtime.

Read more
PLC vs. HMI: Distinguishing the Brain from the Interface in Industrial Automation

PLC vs. HMI: Distinguishing the Brain from the Interface in Industrial Automation

In the realm of industrial automation, distinguishing between a Programmable Logic Controller (PLC) and a Human-Machine Interface (HMI) is fundamental. While both devices work in tandem, they serve distinct purposes. The PLC acts as the "brain" of the operation, executing logic, whereas the HMI serves as the "eyes," allowing operators to monitor and interact with the system. Understanding this synergy is essential for any professional designing robust factory automation solutions.

Read more
Selecting the Right Industrial Automation Solution for Modern Manufacturing

Selecting the Right Industrial Automation Solution for Modern Manufacturing

Choosing an effective industrial automation system starts with a thorough process audit. You must identify tasks that are repetitive, labor-intensive, or prone to human error. Not every process requires high-level automation; therefore, prioritize operations that directly impact throughput and quality. By scoping your needs accurately, you avoid over-investing in unnecessary technology. A balanced approach ensures that your capital expenditure aligns with measurable gains in operational efficiency.

Read more