Skip to content

What are you looking for?


You may also like

Allen-Bradley 1719-AENTR Ex I/O EtherNet/IP Communication AdapterAllen-Bradley 1719-AENTR Ex I/O EtherNet/IP Communication AdapterAllen-Bradley 1719-AENTR Ex I/O EtherNet/IP Communication Adapter
Allen-Bradley 1719-AENTR Ex I/O EtherNet/IP Communication Adapter
Allen-Bradley 1719-AENTR Ex I/O EtherNet/IP Communication Adapter
Allen-Bradley 1719-AENTR Ex I/O EtherNet/IP Communication Adapter

Allen-Bradley 1719-AENTR Ex I/O EtherNet/IP Communication Adapter


Only 10 left - Selling fast

PRODUCT SKU : 1719-AENTR

PRODUCT TYPE : Communication Adapter

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen-Bradley 1719-AENTR acts as the primary communication gateway for the 1719 Ex I/O chassis. This high-performance EtherNet/IP adapter enables seamless data exchange between intrinsically safe field devices and a standard ControlLogix or CompactLogix controller. It facilitates the mounting of I/O modules directly in hazardous locations, reducing the need for expensive explosion-proof enclosures or extensive long-distance cabling. We supply this module as 100% Brand New and Original, ensuring your hazardous area network meets stringent regulatory and safety standards.

Technical Specifications

The 1719-AENTR leverages dual-port Ethernet technology to support advanced network topologies in demanding environments.

  • Manufacturer: Allen-Bradley / Rockwell Automation

  • Product Type: Communication Adapter (Ex I/O)

  • Communication Protocol: EtherNet/IP

  • Network Topology: Supports Device Level Ring (DLR) and Linear

  • Safety Rating: Intrinsically Safe (Ex i)

  • Hazardous Location Ratings: Zone 2, Class 1 / Div 2

  • Input Voltage: 12V DC

  • Power Consumption: 3.9 Watts

  • Module Capacity: Supports up to 45 I/O modules per chassis string

  • Weight: 0.44 lbs (0.20 kg)

Engineering Advantages

  • Direct Hazardous Area Mounting: The 1719-AENTR carries certifications for Zone 2 and Class 1, Division 2 environments. This eliminates the requirement for traditional purging systems or heavy cast-iron enclosures, significantly lowering the total cost of installation.

  • Network Resiliency via DLR: The dual-port design supports Device Level Ring (DLR) topology. This architecture provides hardware-level redundancy; if a cable break occurs, the adapter automatically reroutes traffic in milliseconds, preventing process downtime in critical chemical or oil and gas applications.

  • Intrinsically Safe Integration: The module manages the power and data distribution to the 1719 Ex I/O backplane. It ensures that electrical energy remains below the ignition threshold, providing a native "Ex i" interface for sensors and actuators located in Zone 0 or Zone 1.

  • Simplified System Architecture: By utilizing EtherNet/IP, this adapter allows engineers to treat hazardous area I/O exactly like standard I/O within the Studio 5000 environment. This unified software approach accelerates commissioning and simplifies long-term maintenance.

FAQs

  • Does the 1719-AENTR support high-availability configurations?

    Yes. The adapter supports Device Level Ring (DLR) and can operate within redundant controller architectures. It ensures that the I/O remains accessible even if one network path fails.

  • Can I install this adapter in a Zone 1 area?

    No. The 1719-AENTR itself must reside in a Zone 2 or Class 1, Division 2 area. However, the I/O modules it controls can interface with field devices located in Zone 1 or Zone 0 through the intrinsically safe backplane.

  • What power supply is required for the 1719-AENTR?

    The module requires a 12V DC input. It typically draws power from the 1719-PSDC power supply module mounted within the same 1719 chassis, which regulates the power for the entire I/O assembly.

  • Is this a brand new unit?

    We guarantee that this 1719-AENTR is 100% Brand New and Original. It ships in factory packaging with all original certifications and documentation intact.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Wellhead Control Panel (WHCP) Architecture in Oil and Gas Automation

Wellhead Control Panel (WHCP) Architecture in Oil and Gas Automation

Upstream oil and gas operations rely on specialized field control platforms to manage wellhead extraction safety and hydraulic actuation. A Wellhead Control Panel (WHCP) serves as a dedicated hydraulic and pneumatic power unit designed to operate critical Christmas Tree isolation valves. By interfacing field safety components directly with Programmable Logic Controller (PLC) architecture, a WHCP protects upstream extraction assets against overpressure, catastrophic leaks, and thermal emergencies.

Read more
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more