Skip to content

What are you looking for?


You may also like

ADV557-S00 | Yokogawa CENTUM VP 32-Channel Digital Output ModuleADV557-S00 | Yokogawa CENTUM VP 32-Channel Digital Output ModuleADV557-S00 | Yokogawa CENTUM VP 32-Channel Digital Output Module
ADV557-S00 | Yokogawa CENTUM VP 32-Channel Digital Output Module
ADV557-S00 | Yokogawa CENTUM VP 32-Channel Digital Output Module
ADV557-S00 | Yokogawa CENTUM VP 32-Channel Digital Output Module

ADV557-S00 | Yokogawa CENTUM VP 32-Channel Digital Output Module


Only 10 left - Selling fast

PRODUCT SKU : ADV557-S00

PRODUCT TYPE : Digital Output Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa ADV557-S00 functions as a high-density FIO (Field network I/O) module for the CENTUM VP Integrated Production Control System. This unit provides 32 current-sink transistor outputs designed to drive discrete field devices including solenoid valves, auxiliary relays, and pilot indicators. By integrating advanced pulse-width modulation (PWM) and time-proportional control, the ADV557-S00 enables precise digital regulation for duty-cycle-dependent applications like thermal process control and chemical dosing.

Part Number Breakdown

Yokogawa utilizes a suffix-based logic to define the hardware's functional environment:

Code Specification
ADV557 32-Channel Digital Output Module (Current Sink Type)
-S Standard Type for general-purpose FIO applications
0 Always 0 (Standard Logic)
0 Basic environmental rating (Non-conformal coating)

Technical Specifications

The ADV557-S00 delivers high-speed switching and robust electrical isolation:

  • Output Channels: 32 channels, current-sink (transistor contact)

  • Switching Speed: ≤ 3 ms (Status output); ≤ 10 ms (Mixed pulse/status)

  • Rated Load Voltage: 24 V DC (External)

  • Maximum Load Current: 100 mA per channel

  • Isolation Voltage: 2 kV AC (Signal-to-system)

  • Connection Type: Pressure-clamp terminal block

  • Control Functions: ON/OFF switching, One-shot pulse, Time-proportional control

  • Weight: 0.3 kg

Engineering Advantages

  • Optimized Cabinet Footprint: Consolidating 32 channels into a single module reduces the required rack space. The use of pressure-clamp terminals facilitates high-density wiring, allowing engineers to simplify cable management in space-constrained control rooms.

  • Superior System Protection: 2 kV AC isolation separates field-side transients from the system logic. The module further organizes channels into two groups of 16, preventing localized electrical faults from cascading across the entire I/O board.

  • Precision Duty-Cycle Control: Unlike standard digital outputs, the ADV557-S00 supports time-proportional output. This allows digital outputs to emulate analog behavior, providing smoother control for heaters or dosing pumps without the cost of a dedicated analog output module.

  • Fault-Tolerant Architecture: This module fully supports dual-redundant node configurations. In critical control loops, the system ensures uninterrupted operation by maintaining output states even during a primary module transition.

FAQs

Is this ADV557-S00 unit brand new?

Yes. We supply this product as 100% Brand New, original Yokogawa equipment in its factory-sealed packaging to ensure maximum longevity and reliability.

Can I replace an ADV551 with an ADV557-S00?

While both handle 32-channel digital outputs, the ADV557-S00 features firmware optimized for specific FIO node units and enhanced pulse logic. You must verify your current FIO bus compatibility and CENTUM VP software version before performing a direct swap.

Does this module require external components for inductive loads?

Yes. When driving inductive loads such as large solenoid valves or relays, you must install external flyback diodes. These diodes prevent back-EMF spikes from damaging the transistor output stages.

How does the current-sink output affect my field wiring?

The ADV557-S00 switches the negative (common) side of the load. You must apply the positive 24 V DC supply directly to the field device and return the negative signal through the module's transistor contact.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more