Skip to content

What are you looking for?


You may also like

ADV551-P50/D5A00 | Yokogawa CENTUM VP Digital Output ModuleADV551-P50/D5A00 | Yokogawa CENTUM VP Digital Output ModuleADV551-P50/D5A00 | Yokogawa CENTUM VP Digital Output Module
ADV551-P50/D5A00 | Yokogawa CENTUM VP Digital Output Module
ADV551-P50/D5A00 | Yokogawa CENTUM VP Digital Output Module
ADV551-P50/D5A00 | Yokogawa CENTUM VP Digital Output Module

ADV551-P50/D5A00 | Yokogawa CENTUM VP Digital Output Module


Only 10 left - Selling fast

PRODUCT SKU : ADV551-P50/D5A00

PRODUCT TYPE : Digital Output Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa ADV551-P50/D5A00 operates as a high-density digital output module designed for the CENTUM VP Distributed Control System (DCS). This module drives up to 32 channels of field devices using a current sink format at 24 V DC. It excels in applications requiring not only standard status outputs but also sophisticated Pulse Width Output and Time-Proportional Output functions. We supply this unit as 100% Brand New and Original, ensuring it meets all factory performance benchmarks for your critical automation loops.

Part Number Breakdown

The suffix and option codes for the ADV551 series define its specialized control capabilities and physical interface:

  • ADV551: 32-Channel Digital Output Module (24 V DC, Isolated).

  • -P: Integrates Pulse Width Output and Time-Proportional Output functions.

  • 5: Standard type without status display and without explosion protection.

  • 0: Basic hardware configuration.

  • /D5A00: Includes the ATD5A-00 KS Cable Interface Adapter for rapid 32-channel connectivity.

Technical Specifications

The ADV551-P50/D5A00 delivers precise timing and electrical isolation for demanding industrial loads:

Feature Specification
Output Channels 32 Channels, Current Sink
Rated Load Voltage 24 V DC
Max Load Current 50 mA per channel
External Power Range 20.4 to 26.4 V DC
Response Time ≤ 3 ms (Status) / ≤ 10 ms (Mixed/Pulse)
Pulse Width Range 8 ms to 7200 seconds
Pulse Resolution 8 ms (with max 1 ms delay)
Withstanding Voltage 2 kV AC (Signal to System)
Common Isolation 500 V AC (Every 16 channels)

Engineering Advantages

  • Advanced Timing Control: The pulse width function allows the module to manage complex modulation tasks directly from the I/O level. Engineers use this to control equipment requiring specific ON-durations, ranging from milliseconds to several hours.

  • High-Efficiency Integration: The /D5A00 KS Cable Interface simplifies high-density wiring. By utilizing pre-assembled KS cables, technicians eliminate individual terminal terminations, which reduces installation time by up to 70% and prevents cross-wiring errors.

  • Superior Electrical Protection: A 2 kV AC isolation barrier between the output signals and the system bus shields the DCS core from field-side surges. This robust design prevents localized electrical faults from cascading into system-wide failures.

  • Fast Response Switching: With a status output response time of 3 ms or less, this module handles high-speed interlocking and sequencing tasks with minimal latency, improving overall process safety and throughput.

FAQs

  • What type of loads can the ADV551-P50 drive directly?

    The module drives 24 V DC loads up to 50 mA per channel. It typically controls interposing relays, solenoid valves, or status indicator lamps in a current sink configuration.

  • How does the /D5A00 adapter assist in narrow cabinet spaces?

    The adapter shifts the wiring interface from the module front to a remote terminal board via a single KS cable. This clears the front of the rack, allowing for better airflow and easier maintenance in cramped enclosures.

  • Does the "5" suffix mean it is less durable than other models?

    No. The "5" suffix simply indicates the absence of an integrated status LED display on the front panel and the lack of specific explosion-proof ratings. The internal electronic durability remains identical to other ADV551 variants.

  • Is the pulse width resolution affected by system load?

    The module maintains an 8 ms resolution with a maximum hardware delay of only 1 ms, ensuring consistent pulse accuracy regardless of the communication load on the DCS network.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more