Skip to content

What are you looking for?


You may also like

ADV151-P50 | Yokogawa CENTUM VP 32-Channel Digital Input ModuleADV151-P50 | Yokogawa CENTUM VP 32-Channel Digital Input ModuleADV151-P50 | Yokogawa CENTUM VP 32-Channel Digital Input Module
ADV151-P50 | Yokogawa CENTUM VP 32-Channel Digital Input Module
ADV151-P50 | Yokogawa CENTUM VP 32-Channel Digital Input Module
ADV151-P50 | Yokogawa CENTUM VP 32-Channel Digital Input Module

ADV151-P50 | Yokogawa CENTUM VP 32-Channel Digital Input Module


Only 10 left - Selling fast

PRODUCT SKU : ADV151-P50

PRODUCT TYPE : Digital Input Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa ADV151-P50 functions as a ruggedized, high-density discrete signal interface for the CENTUM VP Distributed Control System (DCS). This 32-channel module captures binary data from field equipment, such as limit switches, motor auxiliary contacts, and pushbutton stations. The "50" designation indicates that this module features G3-level corrosive resistance, making it the primary choice for installations in harsh chemical, oil and gas, or wastewater treatment facilities where atmospheric contaminants are present.

Condition: 100% Brand New and Original Factory Sealed.

Part Number Breakdown: ADV151-P50

Yokogawa uses a specific coding system to define environmental protection and connection styles:

  • ADV151: Digital Input Module (32-channel, 24 V DC, Isolated).

  • -P: Pressure-clamp terminal connection style.

  • 5: With G3 Corrosive Resistance (Conformal coating for $H_2S$, $SO_2$, and $Cl_2$ protection).

  • 0: Basic type hardware specification.

Technical Specifications

The ADV151-P50 provides precise electrical thresholds and environmental hardening for critical process monitoring.

  • Number of Channels: 32, isolated (in groups)

  • Input Signal: 24 V DC (Dry contact or Voltage input)

  • Input Current: 4.1 mA (at 24 V DC)

  • ON Voltage/Current: 18 to 26.4 V DC / $\ge$ 3.0 mA

  • OFF Voltage/Current: $\le$ 5.0 V DC / $\le$ 1.0 mA

  • Withstand Voltage: 1500 V AC between input and system

  • Data Update Cycle: 10 ms

  • Environmental Protection: ISA Standard S71.04 Class G3

  • Current Consumption: 500 mA (at 5 V DC)

Engineering Advantages

  • G3-Rated Corrosive Resistance: The ADV151-P50 features specialized conformal coating on all internal circuit boards. This prevents silver and copper corrosion caused by hydrogen sulfide and other aggressive gases, significantly extending the module's lifespan in unconditioned industrial environments.

  • Maximized Rack Efficiency: Processing 32 channels within a single slot reduces the total number of subracks and nodes required for a project. This high-density architecture allows for smaller control cabinets and lower overall system costs.

  • Industrial-Grade Optical Isolation: The module provides 1500 V AC isolation between field-side inputs and the internal DCS bus. This isolation protects the central processor from electrical transients and ground noise, ensuring continuous system availability.

  • Rapid Logic Updates: A 10 ms update cycle provides the near-instantaneous feedback required for high-speed interlocking and sequence-of-events (SOE) recording.

  • Simplified Field Wiring: The pressure-clamp terminal configuration allows for direct wiring to the module. This eliminates the need for separate external terminal boards in many applications, reducing potential points of failure in the signal loop.

FAQs

  • Does the ADV151-P50 require an external power supply?

    Yes. You must provide an external 24V DC supply to power the field-side contacts (wetting voltage). The module senses the presence or absence of this voltage to determine the logic state.

  • Can I replace an ADV151-P00 with an ADV151-P50?

    Yes. The P50 version offers identical functionality but adds G3 environmental protection. It is a recommended upgrade if your control room is located in a corrosive area.

  • What is the difference between ADV151-P50 and ADV151-P53?

    Both share the same G3 rating and 32-channel input logic. The P53 is a later hardware revision with updated internal sub-components for improved thermal efficiency and stability, but they are generally interchangeable.

  • Is the ADV151-P50 hot-swappable?

    In a redundant I/O configuration, you can replace the module while the system is powered. For non-redundant loops, ensure you follow plant safety procedures, as all 32 inputs will lose signal during the swap.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




  • 5 stars: 4 (80%)
  • 4 stars: 1 (20%)
  • 3 stars: 0 (0%)
  • 2 stars: 0 (0%)
  • 1 star: 0 (0%)
E
Elena

Reliable source for Yokogawa parts. We purchased several ADV151-P50 modules for our wastewater treatment plant. They arrived well-protected and in perfect condition. It is a pleasure to find a supplier that understands the specific technical requirements of DCS modules.

M
Mark

Good service and solid hardware. The product arrived on time and works as expected in our redundant setup. Dropped one star only because the tracking information was updated a bit late, but the product itself is perfect. No issues with the installation.

D
David

Top-tier quality. The high-density 32-channel design is exactly what we needed to optimize our cabinet space. The modules passed all our I/O loop checks on the first try. Will definitely be ordering from this store again for our next upgrade project.

S
Sarah

These ADV151-P50 units are the real deal. We needed to replace some aging I/O cards in a corrosive environment, and this vendor had them in stock when everyone else had lead times of months. Professional service and great communication throughout the order process.

R
Robert

Extremely fast shipping! The modules arrived in original factory-sealed packaging, exactly as described. We are currently integrating these into our CENTUM VP system, and the G3 conformal coating gives us peace of mind for our local climate. Excellent vendor to work with for critical DCS hardware.

Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more