Skip to content

What are you looking for?


You may also like

AAV144-S50 | Yokogawa | HART Analog Input Pressure Transmitter ModuleAAV144-S50 | Yokogawa | HART Analog Input Pressure Transmitter ModuleAAV144-S50 | Yokogawa | HART Analog Input Pressure Transmitter Module
AAV144-S50 | Yokogawa | HART Analog Input Pressure Transmitter Module
AAV144-S50 | Yokogawa | HART Analog Input Pressure Transmitter Module
AAV144-S50 | Yokogawa | HART Analog Input Pressure Transmitter Module

AAV144-S50 | Yokogawa | HART Analog Input Pressure Transmitter Module


Only 10 left - Selling fast

PRODUCT SKU : AAV144-S50

PRODUCT TYPE : Pressure Transmitter Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa AAV144-S50 integrates precision pressure sensing with advanced HART communication protocols to deliver critical process data in demanding industrial environments. This 2-wire transmitter converts mechanical pressure into a stable 4-20mA signal, allowing operators to monitor system integrity in real-time. We provide this unit as a 100% Brand New and Original factory-sealed product, guaranteeing compliance with strict engineering standards.

Part Number Breakdown: AAV144-S50

The Yokogawa AAV144 series follows a specific configuration logic to match specialized field requirements:

Suffix Code Feature Category Specification Details
AAV144 Base Model High-Performance Pressure Transmitter
-S Product Type Standard Industrial Version
5 Output/Comm 4-20mA DC with HART Digital Communication
0 Option Basic Configuration / No Special Options

Technical Specifications

The AAV144-S50 utilizes high-grade metallurgy and electronics to maintain signal fidelity:

  • Measuring Range: Selectable from 0-0.5 MPa up to 0-50 MPa

  • Output Signal: 4-20mA + HART (2-wire loop powered)

  • Accuracy: ±0.1% FS (includes linearity, hysteresis, and repeatability)

  • Wetted Materials: Hastelloy C276 Diaphragm / SUS316L Body

  • Process Connection: 1/2" NPT male or DIN 16288 flange

  • Operating Voltage: 10.5 to 42V DC

  • Protection Rating: IP67 / NEMA 4X

  • Temperature Limits: Process: -40°C to 120°C | Ambient: -30°C to 80°C

Engineering Advantages

The AAV144-S50 solves common site-specific challenges through robust hardware design:

  • Corrosion Resistance: The Hastelloy C276 diaphragm resists aggressive chemical media and sour gas environments, preventing diaphragm rupture and premature sensor failure in volatile process loops.

  • Environmental Sealing: The IP67-rated housing protects internal electronics from high-pressure water jets and dust ingress. This ensures long-term deployment in outdoor installations or wash-down areas without signal drift.

  • HART Intelligence: The digital HART overlay allows engineers to perform remote calibration and diagnostics. This feature eliminates the need for technicians to access hazardous or cramped locations for routine maintenance.

  • Wide Thermal Range: The module operates consistently up to 120°C process temperature. This capability handles steam or high-heat fluid applications without requiring external cooling siphons in many configurations.

FAQs

  • Can the AAV144-S50 operate in hazardous areas?

    The IP67/NEMA 4X rating provides excellent environmental protection. However, you must verify the specific explosion-proof (Ex) or intrinsically safe (IS) certifications on the nameplate if installing in Class I, Div 1 zones.

  • How do I adjust the measuring range?

    You can re-range the device via a HART communicator or Yokogawa’s FieldMate software. The internal electronics allow you to scale the 0-0.5MPa to 0-50MPa span to fit your specific process window.

  • What is the advantage of the 2-wire loop-powered design?

    This design simplifies installation by carrying both power and the 4-20mA signal over a single pair of wires. It reduces wiring costs and minimizes the complexity of the cable infrastructure.

  • Does the ±0.1% accuracy include long-term drift?

    The ±0.1% FS specification covers linearity and hysteresis at the time of calibration. While the AAV144 series exhibits excellent stability, we recommend annual verification to account for extreme process-induced drift.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more