Only 10 left - Selling fast

PRODUCT SKU : AAI835-H50

PRODUCT TYPE : Analog I/O Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Technical Overview

The AAI835-H50 is a specialized high-reliability analog mixing module developed for the Yokogawa CENTUM VP platform. This unit provides 4-channel input and 4-channel output capabilities, specifically designed for applications requiring galvanic isolation between channels. Unlike standard non-isolated modules, the AAI835-H50 ensures that electrical noise or ground loops on one circuit do not propagate to others, maintaining signal integrity in complex process environments.

Equipped with HART digital communication support (indicated by the "H" suffix), this module allows for seamless integration with intelligent field devices. Its high-speed 10 ms data refresh rate ensures precise real-time control for both monitoring and actuation loops.

Detailed Specifications

  • Module Identification: AAI835-H50

  • I/O Configuration: 4-Channel Input / 4-Channel Output

  • Isolation Type: Individual Channel-to-Channel Isolation

  • Signal Protocol: 4 to 20 mA DC with HART Digital Communication

  • Conversion Accuracy: Input: ±16 µA; Output: ±48 µA

  • Data Refresh Period: 10 ms (High-speed synchronous update)

  • Withstanding Voltage: 1500 V AC for 1 minute (Input/Output to System)

  • Transmitter Power Supply: 14.3 V or higher (at 20 mA) to 25.5 V or less

  • Input Impedance: 250 Ω

  • Allowable Load Resistance: 0 to 600 Ω (Output)

  • Temperature Drift: ±16 µA per 10 °C change

  • Power Consumption: 450 mA (5 V DC) / 450 mA (24 V DC)

  • Standard Interface: KS Cable or MIL Connector compatibility

  • Weight: 1.3 kg

Module Comparison: Isolated vs. Non-Isolated

Feature AAI835-H50 (Isolated) AAI841 (Non-Isolated)
Channel Count 4-In / 4-Out 8-In / 8-Out
Isolation Full Channel-to-Channel Shared Common Ground
Noise Immunity Critical for high-EMI zones Suitable for local panels
Communication HART Protocol Analog Only (Standard)

Frequently Asked Questions

  • What is the benefit of channel-to-channel isolation on this module?

    It prevents potential differences between field devices from causing measurement errors or damaging the control system, which is essential for distributed field instrumentation.

  • Does this unit support 2-wire transmitters?

    Yes, the AAI835-H50 provides an integrated power supply for loop-powered devices while maintaining isolation standards.

  • Which control systems is this module compatible with?

    It is natively compatible with Yokogawa CENTUM VP and CENTUM CS 3000 R3 systems.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

Mastering the Factory Acceptance Test (FAT) for PLC Control Panels: An Expert Guide

The Factory Acceptance Test (FAT) is a vital milestone in industrial automation that ensures custom PLC panels meet exact design specifications before dispatch. This guide outlines the step-by-step FAT procedure and key industry best practices to prevent costly site delays and ensure long-term operational success.

Read more
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more
Understanding Types of Noise in Electronic Circuits and Control Systems

Understanding Types of Noise in Electronic Circuits and Control Systems

Signal integrity directly determines measurement accuracy and loop stability across industrial automation environments. Electronic noise introduces unwanted stochastic interference into analog loops, sensor feedback lines, and digital fieldbus networks. Understanding how intrinsic electronic noise and external electromagnetic interference manifest allows control engineers to optimize signal conditioning and shield sensitive instrumentation effectively.

Read more