Skip to content

What are you looking for?


You may also like

AAI143-H00/K4A00 | Yokogawa CENTUM VP 16-Channel HART Isolated Analog Input ModuleAAI143-H00/K4A00 | Yokogawa CENTUM VP 16-Channel HART Isolated Analog Input ModuleAAI143-H00/K4A00 | Yokogawa CENTUM VP 16-Channel HART Isolated Analog Input Module
AAI143-H00/K4A00 | Yokogawa CENTUM VP 16-Channel HART Isolated Analog Input Module
AAI143-H00/K4A00 | Yokogawa CENTUM VP 16-Channel HART Isolated Analog Input Module
AAI143-H00/K4A00 | Yokogawa CENTUM VP 16-Channel HART Isolated Analog Input Module

AAI143-H00/K4A00 | Yokogawa CENTUM VP 16-Channel HART Isolated Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : AAI143-H00/K4A00

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The AAI143-H00/K4A00 from Yokogawa is a robust analog input module designed for distributed control systems. It provides 16 isolated input channels capable of handling 4–20 mA DC signals, ensuring accurate and stable data acquisition in industrial automation environments.

This model supports HART communication, enabling remote diagnostics and transmitter configuration. The suffix codes define its configuration: “H” indicates HART protocol support, “0” denotes the basic type, and “/K4A00” specifies the inclusion of a KS cable interface adapter (ATK4A-00) for connecting to terminal boards.

Technical Specifications

  • Model / Order Number: AAI143-H00/K4A00

  • Manufacturer: Yokogawa Electric Corporation

  • Type: Analog Input Module

  • Channels: 16 isolated analog inputs

  • Signal Range: 4–20 mA DC

  • Allowable Input Current: Up to 24 mA

  • Input Resistance:

    • Power ON: 270 Ω (20 mA) to 350 Ω (4 mA)

    • Power OFF: ≥500 kΩ

  • Accuracy: ±16 µA

  • Temperature Drift: ±16 µA per 10°C

  • Data Update Period: 10 ms

  • Transmitter Power Supply: 19.0–25.5 V (current limit 25 mA)

  • Isolation Voltage: 1500 V AC between input and system (1 minute)

  • Current Consumption: 230 mA (5 V DC), 540 mA (24 V DC)

  • External Connections: Pressure clamp terminal, MIL connector cable, KS cable

  • Weight: Approx. 0.3 kg

Application Scenarios

  • Signal acquisition from field transmitters in process industries

  • Integration into Yokogawa CENTUM VP and CS 3000 systems

  • Environments requiring HART communication for diagnostics and configuration

  • Safety‑critical monitoring in petrochemical, oil & gas, and power generation

FAQ

Q: How many channels does the AAI143-H00/K4A00 support?  A: It provides 16 isolated analog input channels.

Q: What does the /K4A00 option mean?  A: It indicates the module is supplied with a KS cable interface adapter (ATK4A-00).

Q: Does the module support HART communication?  A: Yes, the “H” suffix confirms HART protocol compatibility.

Q: What is the accuracy of this module?  A: ±16 µA across the rated input range.

Q: Is the module explosion‑proof?  A: No, the suffix “5” specifies that it is a non‑explosion protected type.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Securing SCADA Systems in Industrial Automation

Securing SCADA Systems in Industrial Automation

Supervisory Control and Data Acquisition (SCADA) systems are central to industrial automation, enabling PLC, DCS, and factory automation processes. Because they manage critical infrastructure, they must be protected against environmental hazards, electronic threats, and cyberattacks. A layered security approach ensures resilience and reliability.

Read more
Importance of Proper Grounding in Industrial Automation and Electronic Control Systems

Importance of Proper Grounding in Industrial Automation and Electronic Control Systems

This article explains the importance of proper grounding in industrial automation systems such as PLC, DCS, and control networks. It discusses how grounding improves safety, reduces electrical noise, and protects sensitive electronics from lightning, switching transients, and interference, while outlining practical installation practices for reliable factory automation operations.

Read more
Electrical Ground Loop Problems in Industrial Automation and How to Eliminate Them

Electrical Ground Loop Problems in Industrial Automation and How to Eliminate Them

This article explains how ground loops impact industrial automation systems such as PLC, DCS, and factory control networks. It outlines the causes of signal noise and presents practical solutions including proper grounding design, signal reference grids, fiber-optic communication, protocol conversion, and cable shielding to improve reliability in control systems.

Read more