PRODUCT SKU : 8C-PAIM01

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Description

The 8C-PAIM01 (P/N 51454358-175) is a high-density Analog Input (AI) module specifically engineered for the Honeywell Experion PKS Series 8 platform. This module serves as a high-precision interface for measuring process variables such as pressure, temperature, flow, and level. It is designed to convert field signals into digital data for processing by the C300 controller. Unlike standard AI modules, the 8C-PAIM01 is optimized for high-reliability data acquisition with advanced filtering to mitigate electromagnetic interference (EMI) commonly found in industrial switchrooms.

Specifications

The following technical parameters define the operational boundaries and performance metrics for the 8C-PAIM01 (51454358-175) hardware.

  • Input Channels: 16 differential channels

  • Input Signal Types: 4-20 mA or 1-5 VDC (software configurable)

  • A/D Converter Resolution: 16-bit

  • Accuracy: ±0.075% of full scale (at 25°C)

  • Input Impedance: 250 Ohms (for mA signals) / >10 MOhms (for Voltage)

  • Common Mode Rejection: >100 dB at 50/60 Hz

  • Scan Rate: 10 ms (all 16 channels)

  • Operating Temperature: -40°C to +70°C (-40°F to +158°F)

  • Isolation Voltage: 2500 VDC (Logic-to-field)

  • Power Dissipation: 3.8 W maximum

  • Conformal Coating: Standard G3 compliance for harsh environments

System Implementation and Diagnostics

Integration of the 8C-PAIM01 (51454358-175) into the Series 8 environment is facilitated through the Input/Output Termination Assembly (IOTA). The module supports "Hot Swap" functionality, allowing for live replacement without disrupting the power or communication to adjacent modules. Diagnostic features include open-wire detection, out-of-range alarms, and internal module self-tests, which are reported in real-time to the Experion system status display to minimize troubleshooting time.

Frequently Asked Questions

Does the 8C-PAIM01 support HART digital communication?No, the 8C-PAIM01 is a high-level analog input module focused on pure signal acquisition. For applications requiring HART protocol pass-through to FDM (Field Device Manager), the HART-enabled variant (e.g., 8C-PAIH01) should be utilized.

Can this module be used in a redundant configuration?Yes, when mounted on a redundant IOTA, a pair of 8C-PAIM01 modules operates in a secondary-tracking mode, providing seamless failover if the primary module detects an internal fault or loss of signal integrity.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

Strategic Selection: Choosing the Right SCADA Software for Your PLC Project

In industrial automation, the SCADA (Supervisory Control and Data Acquisition) system acts as the bridge between raw machine data and actionable human intelligence. Selecting the incorrect software platform can lead to integration bottlenecks, scalability issues, and excessive long-term maintenance costs. As an automation consultant with 15 years of experience, I have guided many projects through the selection process. Below are the essential criteria for choosing a platform that ensures both performance and longevity.

Read more
Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

Ensuring Operational Continuity: The Strategic Value of Redundant Automation Systems

In modern industrial landscapes, unplanned downtime is the ultimate adversary. For sectors relying on complex PLC and DCS architectures, a single hardware failure can trigger catastrophic production losses. Therefore, implementing redundant automation systems is no longer a luxury; it is a fundamental requirement for mission-critical operations. In this article, I analyze why redundancy remains the backbone of reliable industrial infrastructure.

Read more
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more