Only 10 left - Selling fast

PRODUCT SKU : 51402457-200

PRODUCT TYPE : Digital Output Relay Interface Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Honeywell 51402497-200 (Model: TP-DSOEP1-100) functions as a high-voltage digital output relay interface within the Experion Process Knowledge System (PKS) architecture. This module isolates and routes high-voltage digital control signals from the controller to field-level actuators, motor starters, and final control elements. It provides an authentic, high-integrity physical interface that safeguards upstream control processors from field electrical transients.

Technical Specifications

Parameter Specification
Brand / Manufacturer Honeywell
Part Number 51402497-200
Model Number TP-DSOEP1-100
System Compatibility Honeywell Experion PKS
Functional Classification Digital output relay interface
Voltage Class High-voltage digital output
Redundancy Configuration Non-redundant
Environmental Protection Protective conformal coating
Dimensions 12.7 × 12.7 × 12.7 cm
Weight Approximately 0.8 kg
Mounting Options Desktop or panel mount
Country of Origin USA
Product Condition 100% Original Brand New
Warranty Period 12 Months

Engineering Advantages

  • Corrosive Environment Mitigation: The factory-applied protective conformal coating shields the internal circuitry against airborne contaminants, moisture, and corrosive gases. This chemical barrier prevents trace degradation and dendrite growth in harsh chemical, oil and gas, or wastewater treatment facilities.

  • High-Voltage Isolation: The integrated physical relays separate low-voltage control logic from high-voltage field execution. This design stops electrical noise, surges, and back-EMF from migrating back into the core Experion PKS controller backbone.

  • Flexible Footprint Deployment: The compact $12.7 \times 12.7 \times 12.7\text{ cm}$ form factor supports both standard panel mounting and temporary desktop testing setups. Engineers can deploy this module in crowded marshaling cabinets without redesigning existing rail layouts.

FAQs

  • Does this module come with factory warranties and original packaging?

    Yes. We supply this product as a 100% original, brand-new unit from factory stock. It includes Honeywell's complete 12-month warranty coverage from the date of purchase.

  • Can I use the 51402497-200 module in a redundant Experion PKS I/O slot?

    No. The TP-DSOEP1-100 features a strictly non-redundant hardware configuration. You must assign it to standard, single-channel non-redundant loops within your Experion PKS system architecture.

  • What specific protection does the conformal coating provide during installation?

    The coating prevents accidental short circuits caused by conductive dust or high humidity during commissioning. However, engineers must still maintain standard ESD grounding protocols and clean panel environments during physical wire termination.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more