Skip to content

What are you looking for?


You may also like

51305072-400 Honeywell | TDC 3000 LCN Input/Output Board51305072-400 Honeywell | TDC 3000 LCN Input/Output Board51305072-400 Honeywell | TDC 3000 LCN Input/Output Board
51305072-400 Honeywell | TDC 3000 LCN Input/Output Board
51305072-400 Honeywell | TDC 3000 LCN Input/Output Board
51305072-400 Honeywell | TDC 3000 LCN Input/Output Board

51305072-400 Honeywell | TDC 3000 LCN Input/Output Board


Only 10 left - Selling fast

PRODUCT SKU : 51305072-400

PRODUCT TYPE : Input/Output Board

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Honeywell 51305072-400 serves as a critical Local Control Network (LCN) Input/Output board within the legacy TDC 3000 Distributed Control System (DCS) ecosystem. This high-performance hardware assembly executes real-time data exchange between field termination units and the primary LCN processing node, ensuring flawless synchronization of process variables. We distribute this component exclusively in 100% brand new, original factory-sealed condition to guarantee original specifications, preserve signal integrity, and eliminate unexpected plant downtime.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model Number 51305072-400
Product Type LCN Input/Output Board
System Family TDC 3000 / TotalPlant Solution (TPS)
Country of Origin United States (USA)
Dimensions (H x W x D) 12.7 cm x 12.7 cm x 12.7 cm (5.0" x 5.0" x 5.0")
Net Weight 0.8 kg (1.76 lbs)
Form Factor Cube-chassis compatible interface module

Engineering Advantages

  • Maximizes Cubicle Space Efficiency: The unique cubic 12.7 cm form factor allows control engineers to optimize cabinet density, packing critical network routing interfaces into tight, square rack spaces where traditional rectangular cards fail to fit.

  • Shields Signals Against Severe EMI: Built with heavy-duty ground planes and industrial-grade shielding, the board repels harsh electromagnetic interference (EMI) originating from nearby high-voltage variable frequency drives (VFDs) and heavy machinery.

  • Simplifies Drop-In Field Retrofits: Because this board matches the exact mechanical footprint and backplane pinouts of standard TDC 3000 chassis, instrumentation techs can swap out malfunctioning modules instantly without re-wiring field terminals or rewriting controller code.

  • Ensures Deterministic Data Control: The on-board bus transceiver circuitry prioritizes mission-critical I/O interrupts, eliminating data packet collisions across the LCN and providing predictable millisecond-level responsiveness for safety-critical loops.

FAQs

  • Does this 51305072-400 board come with factory packaging or is it open-box surplus?

    We supply this product strictly as a 100% brand new, factory-sealed unit direct from original production lots. It features the authentic manufacturer labels, anti-static shielding bags, and full factory trace documentation.

  • Can I use this board to replace older revisions like the -100 or -200 series?

    The -400 suffix designates an upgraded, optimized component profile that offers backward compatibility with older variations of this LCN chassis series. Review your specific system architecture configuration or contact our technical support staff to verify complete firmware compatibility.

  • What handling precautions should installation engineers take during deployment?

    The 51305072-400 contains sensitive complementary metal-oxide-semiconductor (CMOS) components. Technicians must wear a grounded electrostatic discharge (ESD) wrist strap, isolate the rack power supply, and slide the board into the designated chassis guides without applying excessive physical force to the backplane pins.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Demystifying the DDE Protocol in Legacy Industrial Automation Systems

Modern control systems rely heavily on seamless interprocess communication to exchange operational data between software programs. Microsoft first introduced the Dynamic Data Exchange (DDE) protocol in 1987 to enable real-time data sharing. In factory automation, DDE served as an early bridge between control software and Windows desktop applications. Therefore, understanding DDE mechanics provides crucial insights into how legacy industrial networks established software-level connectivity.

Read more
Demystifying CPU Communication Ports in Siemens PLC Architectures

Demystifying CPU Communication Ports in Siemens PLC Architectures

Industrial automation relies heavily on robust data exchange between devices. Without seamless connectivity, field instruments, network switches, human-machine interfaces, and programmable logic controllers cannot coordinate effectively. Therefore, understanding the various CPU communication ports available in Siemens hardware ensures efficient factory automation design and seamless system integration.

Read more
Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Industrial automation relies heavily on programmable logic controllers (PLCs) to manage complex manufacturing processes. Many engineers dive straight into programming without mastering the underlying architecture. However, understanding how a PLC CPU executes a program ensures reliable system design. Therefore, mastering the scan cycle optimizes both performance and troubleshooting in modern control systems.

Read more