Product Details

The Bently Nevada 330103-00-17-10-02-05 is an eddy current proximity probe from the 3300 XL 8 mm series for non-contact shaft displacement and vibration measurement. This configuration features an M10 x 1 case thread, a 0 mm unthreaded length (option 00), a 170 mm overall case length (option 17), a 1.0 m (3.3 ft) standard cable with a miniature coaxial ClickLoc connector (option 02), and CSA, ATEX, and IECEx approvals (option 05).

Measurement Range and Electrical Characteristics

This probe provides a 2 mm (80 mils) linear range spanning 0.25 mm to 2.3 mm (10 to 90 mils), with an output voltage of approximately -1 to -17 VDC across the linear span. For standard radial vibration setups, set the gap to -9 VDC, corresponding to approximately 1.27 mm (50 mils).

At the 1.0 m probe length, DC resistance is 7.59 ohm +/- 0.50. Field wiring supports 0.2 to 1.5 mm2 (16-24 AWG) on 3-conductor shielded triad cable, with up to 305 m (1,000 ft) maximum extension cable length between sensor and monitor.

Mechanical Construction and Hazardous Area Ratings

The probe combines a polyphenylene sulfide (PPS) tip with an AISI 303 or 304 stainless steel (SST) case, an M10 x 1 thread (15 mm maximum thread engagement), and a Viton O-ring pressure seal that is not pressure tested prior to shipment. Standard temperature rating is -52 deg C to +177 deg C (-62 deg F to +350 deg F), with extended ratings listed for the tip (-52 deg C to +218 deg C) and cable (-51 deg C to +260 deg C), while weight is 323 g/m (11.4 oz).

Agency approvals (option 05) cover CSA, ATEX, and IECEx across EPL Ga/Gc, EPL Dc, and Division classifications, with temperature classes T1 through T5 and dust classes defined over specified ambient ranges. Note that low-temperature exposure below -34 deg C risks pressure seal failure.

Installation and Wiring Guidelines

  1. Use 3-conductor shielded triad cable with tinned conductors sized from 0.2 to 1.5 mm2 (16-24 AWG) for field wiring.
  2. Keep total field wiring under 305 m (1,000 ft) between sensor and monitor, and check frequency response data for high-frequency rolloff over longer cable runs.
  3. Adjust the probe gap to approximately -9 VDC (about 1.27 mm / 50 mils) for standard radial vibration measurement.
  4. Do not expose the probe below -34 deg C if avoiding pressure seal failure is required for the application.

Technical Specifications

Parameter Specification
Model 330103-00-17-10-02-05
Brand Bently Nevada
Series / Product Type 3300 XL 8 mm Proximity Probe
Linear Range 2 mm (80 mils), spanning 0.25 mm to 2.3 mm (10 to 90 mils)
Output Voltage Approx. -1 to -17 VDC over full linear range
Recommended Radial Vibration Gap -9 VDC (approx. 1.27 mm / 50 mils)
Probe DC Resistance 7.59 ohm +/- 0.50 (at 1.0 m probe length)
Field Wiring 0.2 to 1.5 mm2 (16-24 AWG), 3-conductor shielded triad cable
Maximum Extension Cable Length 305 m (1,000 ft) between sensor and monitor
Case Thread M10 x 1 (15 mm max thread engagement)
Unthreaded Length 0 mm (option 00)
Overall Case Length 170 mm (option 17)
Total Length 1.0 m / 3.3 ft (option 10)
Connector and Cable Type Miniature coaxial ClickLoc connector with standard cable (option 02)
Tip Material Polyphenylene sulfide (PPS)
Case Material AISI 303 or 304 stainless steel (SST)
Pressure Seal Viton O-ring (not pressure tested before shipment)
Agency Approvals CSA, ATEX, IECEx (option 05)
Hazardous Area Ratings ia (Zone 0, Div 1): AEx/Ex ia IIC T5...T1 Ga, Class I, II, III; nA, ec (Zone 2, Div 2): AEx/Ex nA IIC T5...T1 Gc, Class I, Div 2; EPL Ga/Gc (T1 to T5) and EPL Dc (T280 deg C to T90 deg C) per ambient limits
Standard Temperature Range -52 deg C to +177 deg C (-62 deg F to +350 deg F)
Extended Temperature Range Tip: -52 deg C to +218 deg C; Cable: -51 deg C to +260 deg C
Relative Humidity Performance Less than 3% ASF change at 93% RH (IEC 68-2-3, 56 days)
Weight 323 g/m (11.4 oz)

Frequently Asked Questions

Q: What gap voltage is recommended for radial vibration monitoring with 330103-00-17-10-02-05?

A: Set the gap to approximately -9 VDC, which corresponds to about 1.27 mm (50 mils) within the 0.25 mm to 2.3 mm (10 to 90 mils) linear range.

Q: Is the pressure seal on this probe pressure tested prior to shipment, and what low-temperature limit applies?

A: The Viton O-ring pressure seal is not pressure tested before shipment. Avoid exposing the probe below -34 deg C to prevent pressure seal failure, and verify applicable hazardous-area temperature class limits for your installation.

Q: What field wiring size and maximum cable length apply between the sensor and monitor?

A: Field wiring uses 0.2 to 1.5 mm2 (16-24 AWG) 3-conductor shielded triad cable, with a maximum extension length of 305 m (1,000 ft) between sensor and monitor. Longer runs can introduce high-frequency rolloff, so check the frequency response curve for your setup.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Essential Technical Glossary of Electrical Grounding and Bonding in Industrial Automation

Essential Technical Glossary of Electrical Grounding and Bonding in Industrial Automation

In industrial automation, precise grounding terminology prevents catastrophic equipment failure. Therefore, engineers must master the foundational concepts of earth and ground. Earth represents the conductive mass of the planet, providing a zero-potential reference point. Ground defines a deliberate or accidental connection between an electrical circuit and earth. Furthermore, an effectively grounded system maintains low impedance to prevent hazardous voltage buildups during electrical faults.

Read more
Essential Guide to Grounding Electronic Equipment in Industrial Automation

Essential Guide to Grounding Electronic Equipment in Industrial Automation

Industrial automation systems require robust grounding for personal safety and fault clearance. Safety grounding minimizes touch potential across exposed metallic enclosures. It ensures rapid clearance of fuses during electrical faults. However, electronic equipment introduces unique performance requirements. Solid-state devices operate at high speeds. Therefore, they exhibit extreme sensitivity to minor voltage transients. Facility engineers must balance electrical safety with operational signal integrity.

Read more
Engineering Guide to Selecting Electrical Earthing and Grounding Components in Industrial Automation

Engineering Guide to Selecting Electrical Earthing and Grounding Components in Industrial Automation

The overall reliability of any industrial automation network relies heavily on its grounding components. Control systems, PLCs, and distributed control systems (DCS) require rigorous earthing to mitigate electrical noise and faults. Engineers must select each component with extreme care. Furthermore, proper interconnection methods dictate whether a facility operates safely or suffers from chronic signal disruption.

Read more