Product Details
The Bently Nevada 330102-10-45-10-02-RU is an 8 mm proximity probe from the 3300 XL series for non-contact shaft displacement and vibration measurement. The provided specification identifies this model as a 3300 XL 8 mm proximity probe with a 2 mm linear range (0.25-2.3 mm, -1 to -17 VDC), a polyphenylene sulfide (PPS) tip, an AISI 303/304 stainless steel case, and a standard operating range from -62 deg F to +350 deg F.
Electrical and Measurement Parameters
In a proximity measurement loop, this 8 mm probe covers a 2 mm linear range from 0.25 mm to 2.3 mm with an output span of -1 to -17 VDC. DC resistance is listed as 7.59 ohm +/- 0.5 ohm, so verify signal conditioning and loop compatibility with the connected transducer hardware.
Extended temperature ratings in the source data list -62 deg F to +425 deg F for the tip and -60 deg F to +500 deg F for the cable, alongside 93% humidity tolerance compliant with IEC 68-2-3. Confirm exact environmental limits for your specific installation before deployment.
Mechanical Construction
The probe features a PPS tip, an AISI 303 or 304 stainless steel (SST) case, and a Viton O-ring seal. Mechanical details list a 0.563 in maximum thread engagement and a weight of 323 g/m.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | 330102-10-45-10-02-RU |
| Brand | Bently Nevada |
| Series / Product Type | 3300 XL / 3300 XL 8 mm Proximity Probe |
| Linear Range | 2 mm (0.25-2.3 mm) |
| Output Range | -1 to -17 VDC |
| DC Resistance | 7.59 ohm +/- 0.5 ohm |
| Maximum Thread Engagement | 0.563 in |
| Tip Material | PPS |
| Case Material | AISI 303/304 SST |
| Seal | Viton O-ring |
| Standard Operating Temperature | -62 deg F to +350 deg F |
| Extended Temperature Rating | Tip: -62 deg F to +425 deg F; Cable: -60 deg F to +500 deg F |
| Humidity Tolerance | 93% humidity (IEC 68-2-3 compliant) |
| Weight | 323 g/m |
Frequently Asked Questions
Q: What linear range and output voltage are specified for 330102-10-45-10-02-RU?
A: The probe specifies a 2 mm linear range spanning 0.25 mm to 2.3 mm with an output of -1 to -17 VDC. Confirm matching transducer calibration and signal range with your monitoring system before use.
Q: What temperature ratings and materials are listed in the specification for this model?
A: Standard operation is listed from -62 deg F to +350 deg F, with extended ratings of -62 deg F to +425 deg F for the tip and -60 deg F to +500 deg F for the cable, plus 93% humidity tolerance per IEC 68-2-3. Construction specifies a PPS tip, AISI 303/304 SST case, and Viton O-ring seal.
Additional Information
- 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
- 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
- 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
- Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
- Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
- Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.