Skip to content

What are you looking for?


You may also like

2711P-T15C4A8 | Allen-Bradley | PanelView Plus 6 Operator Terminal2711P-T15C4A8 | Allen-Bradley | PanelView Plus 6 Operator Terminal2711P-T15C4A8 | Allen-Bradley | PanelView Plus 6 Operator Terminal
2711P-T15C4A8 | Allen-Bradley | PanelView Plus 6 Operator Terminal
2711P-T15C4A8 | Allen-Bradley | PanelView Plus 6 Operator Terminal
2711P-T15C4A8 | Allen-Bradley | PanelView Plus 6 Operator Terminal

2711P-T15C4A8 | Allen-Bradley | PanelView Plus 6 Operator Terminal


Only 10 left - Selling fast

PRODUCT SKU : 2711P-T15C4A8

PRODUCT TYPE : PanelView

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview
The 2711P-T15C4A8 is an Allen-Bradley PanelView Plus 6 graphic terminal offering a 15-inch color touch display with advanced TFT technology. Designed for industrial applications, it supports versatile communication protocols and provides high reliability and intuitive operator control.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: PanelView Plus 6

  • Part Number: 2711P-T15C4A8

  • Product Type: Graphic Operator Terminal

  • Display Size: 15.0 in.

  • Display Type: Color active-matrix TFT

  • Display Area: 304 × 228 mm (12 × 9 in.)

  • Resolution: 1024 × 768, 18-bit color

  • Operator Input: Touchscreen, 8-wire analog resistive

  • Touch Actuation: 1 million presses, operating force 10–110 g

  • Memory: 512 MB RAM, 512 MB nonvolatile (≈79 MB available for user)

  • Battery: Real-time clock, ±2 min/month, 4-year typical life, field-replaceable (2711P-RY2032)

  • Communication Ports: Ethernet, RS-232, DH485, 2 USB hosts

  • Input Voltage Range: 100–240V AC, 50–60 Hz

  • Power Consumption: Max 160 VA, Typical 65 VA

  • Backlight Module: 2711P-RL15C

  • Communication Cable: 2711-NC13

  • Series: A and B

  • Weight: 6.0 lbs (2.72 kg)

Key Features

  • Large 15-Inch Touch Display: High-resolution color graphics for detailed operator interface

  • Versatile Connectivity: Supports Ethernet, RS-232, DH485, and USB for flexible integration

  • Durable Touch Interface: Analog resistive touchscreen designed for over 1 million presses

  • Memory and Storage: Sufficient RAM and nonvolatile memory for complex HMI applications

  • Reliable Real-Time Clock: Battery-backed clock maintains timestamp accuracy for critical operations

  • Industrial Design: Robust, suitable for harsh environments with PanelView Plus 6 reliability

Applications

  • Monitoring and controlling industrial processes

  • Human-machine interface (HMI) for manufacturing systems

  • Replacement or upgrade for existing PanelView Plus 6 installations

FAQs

Q: What type of touch technology does the 2711P-T15C4A8 use?
A: It features an 8-wire analog resistive touchscreen with 1 million actuation cycles.

Q: What communication interfaces are available?
A: Ethernet, RS-232, DH485, and dual USB host ports.

Q: Can the battery be replaced in the field?
A: Yes, the real-time clock uses a replaceable CR2032 coin-cell battery (cat. no. 2711P-RY2032).

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering VFD Braking Theory and Mechanical Brake Sequencing in Industrial Automation

Mastering VFD Braking Theory and Mechanical Brake Sequencing in Industrial Automation

In industrial automation, variable frequency drives (VFDs) regulate motor speed and torque across manufacturing plants and material handling systems. However, certain heavy-duty applications experience external loads that can rotate the motor shaft without an active command. For instance, gravity pulls loads downward in unanchored hoisting equipment. Therefore, engineers integrate mechanical brakes with VFD logic to maintain absolute safety and prevent structural damage or personnel injury during shutdowns.

Read more
Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Industrial automation engineers frequently encounter liquid level regulation challenges across diverse process plants. Traditional ON-OFF control mechanisms often disrupt system stability due to abrupt actuator switching. Therefore, upgrading to closed-loop architectures like proportional control yields smoother responses. In a typical PLC environment, such as Siemens TIA Portal, engineers utilize closed-loop feedback to minimize process errors without requiring full PID complexity.

Read more
Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

In industrial automation, programmable logic controllers (PLCs) serve as the core intelligence of modern factory automation and distributed control systems (DCS). Understanding how a PLC transitions between modes is vital for maintenance engineers. Typically, a PLC operates across four primary modes: Run, Stop, Start-Up, and Hold. When power is applied, the system immediately boots into Stop mode before initiating the Start-Up sequence. If the controller encounters a critical error during execution, it automatically reverts to Stop mode to prevent equipment damage. Therefore, monitoring these state transitions helps technicians maintain high system availability.

Read more