Skip to content

What are you looking for?


You may also like

2711P-K6C20D8 | Allen Bradley | PanelView Plus 6 600 Color Keypad Terminal2711P-K6C20D8 | Allen Bradley | PanelView Plus 6 600 Color Keypad Terminal2711P-K6C20D8 | Allen Bradley | PanelView Plus 6 600 Color Keypad Terminal
2711P-K6C20D8 | Allen Bradley | PanelView Plus 6 600 Color Keypad Terminal
2711P-K6C20D8 | Allen Bradley | PanelView Plus 6 600 Color Keypad Terminal
2711P-K6C20D8 | Allen Bradley | PanelView Plus 6 600 Color Keypad Terminal

2711P-K6C20D8 | Allen Bradley | PanelView Plus 6 600 Color Keypad Terminal


Only 10 left - Selling fast

PRODUCT SKU : 2711P-K6C20D8

PRODUCT TYPE : Keypad Terminal

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 2711P-K6C20D8 serves as a high-performance operator interface for the PanelView Plus 6 600 platform. This terminal utilizes a tactile keypad for precise machine control and a 5.7-inch color display for real-time process visualization. It excels in environments where operators require physical button feedback or wear heavy protective gear. We provide this unit as 100% Brand New original factory stock, ensuring full compatibility with modern FactoryTalk View ME applications and industrial Ethernet networks.

Technical Specifications

The 2711P-K6C20D8 integrates robust processing power with versatile communication options for seamless PLC integration.

Feature Specification
Manufacturer Allen Bradley (Rockwell Automation)
Model 2711P-K6C20D8
Display Size 5.7 inches
Display Color Full Color TFT
Operator Input Stainless-steel Membrane Keypad
Communication Ports Ethernet (10/100 Mbps) and RS-232
Input Power 18–30V DC (24V DC Nominal)
Internal Memory 256 MB RAM
Backlight Long-life LED (Non-replaceable)
Weight 1.94 lbs (0.88 kg)
Series Series A and Series B Supported

Engineering Advantages

  • Tactile Precision in Harsh Environments: Unlike touchscreen-only models, the 2711P-K6C20D8 features a rugged membrane keypad. This physical interface prevents accidental triggers from moisture, oil splashes, or debris on the screen surface. Operators receive definitive tactile feedback, which is critical for safety-sensitive manual adjustments.

  • Dual-Protocol Communication: The onboard Ethernet and RS-232 ports allow for simultaneous network connectivity and point-to-point serial communication. This flexibility enables the HMI to poll data from a primary ControlLogix controller over EtherNet/IP while maintaining a legacy link to a barcode scanner or printer via RS-232.

  • Optimized for Tight Enclosures: The compact 5.7-inch form factor and 1.94 lbs lightweight design permit installation in shallow control cabinets. The 24V DC power input aligns with standard industrial power rails, eliminating the need for bulky AC transformers inside the console.

  • Enhanced Data Handling: With 256 MB of RAM and the Plus 6 architecture, this terminal executes complex graphic screens and large alarm logs without latency. It processes high-speed data transitions efficiently, providing operators with instantaneous system status updates.

FAQs

  • Can I use the 2711P-K6C20D8 as a direct replacement for an older PanelView Plus 600?

    Yes. This model serves as the upgraded "Plus 6" version. It offers faster processing and improved memory management compared to standard legacy units. Ensure your FactoryTalk View ME project matches the firmware version of the new hardware for a seamless transition.

  • What is the recommended communication cable for the RS-232 port?

    Use the 2711-NC13 communication cable for reliable serial data transfer. This cable provides the necessary shielding to protect signal integrity against electromagnetic interference (EMI) typically found near variable frequency drives (VFDs) and high-power motors.

  • Does this unit support external storage for data logging?

    The 2711P-K6C20D8 includes USB ports that support standard flash drives. This allows you to export CSV-formatted data logs, trend information, and alarm histories for external analysis or regulatory compliance reporting.

  • How do I ensure the unit remains waterproof after installation?

    Always use the provided mounting gasket and clips during installation. Tighten the clips to the specified torque to create a uniform seal against the panel door. When properly mounted, the front face maintains its NEMA/IP rating, protecting internal electronics from washdown procedures and dust.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering PLC Programming: Best Practices for Robust Industrial Automation

Mastering PLC Programming: Best Practices for Robust Industrial Automation

Writing clean PLC code requires discipline, especially regarding memory management. Avoid overusing SET and RESET instructions, as they often complicate debugging. If multiple rungs control the same bit, troubleshooting becomes a nightmare. Instead, focus on energizing a bit in only one location. If your logic requires complex conditions, use branches within a single rung. This approach keeps your code readable, maintainable, and significantly easier to audit during downtime.

Read more
PLC vs. HMI: Distinguishing the Brain from the Interface in Industrial Automation

PLC vs. HMI: Distinguishing the Brain from the Interface in Industrial Automation

In the realm of industrial automation, distinguishing between a Programmable Logic Controller (PLC) and a Human-Machine Interface (HMI) is fundamental. While both devices work in tandem, they serve distinct purposes. The PLC acts as the "brain" of the operation, executing logic, whereas the HMI serves as the "eyes," allowing operators to monitor and interact with the system. Understanding this synergy is essential for any professional designing robust factory automation solutions.

Read more
Selecting the Right Industrial Automation Solution for Modern Manufacturing

Selecting the Right Industrial Automation Solution for Modern Manufacturing

Choosing an effective industrial automation system starts with a thorough process audit. You must identify tasks that are repetitive, labor-intensive, or prone to human error. Not every process requires high-level automation; therefore, prioritize operations that directly impact throughput and quality. By scoping your needs accurately, you avoid over-investing in unnecessary technology. A balanced approach ensures that your capital expenditure aligns with measurable gains in operational efficiency.

Read more