Skip to content

What are you looking for?


You may also like

2711-NL1 | Allen-Bradley | PanelView 550 Replacement Backlight Lamp2711-NL1 | Allen-Bradley | PanelView 550 Replacement Backlight Lamp2711-NL1 | Allen-Bradley | PanelView 550 Replacement Backlight Lamp
2711-NL1 | Allen-Bradley | PanelView 550 Replacement Backlight Lamp
2711-NL1 | Allen-Bradley | PanelView 550 Replacement Backlight Lamp
2711-NL1 | Allen-Bradley | PanelView 550 Replacement Backlight Lamp

2711-NL1 | Allen-Bradley | PanelView 550 Replacement Backlight Lamp


Only 10 left - Selling fast

PRODUCT SKU : 2711-NL1

PRODUCT TYPE : Backlight Lamp

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The 2711-NL1 serves as the essential integrated replacement backlight for the Allen-Bradley PanelView 550 terminal series. This module restores full visual clarity to monochrome LCD displays that have dimmed or failed due to lamp exhaustion. Utilizing a high-output halogen source paired with fiber-optic illumination, the 2711-NL1 ensures uniform brightness across the operator interface. We provide this component as 100% Brand New original stock to guarantee immediate restoration of HMI usability in mission-critical control environments.

Technical Specifications

The 2711-NL1 features precise electrical and optical parameters to match the original PanelView 550 chassis requirements:

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Product Line PanelView 550
Display Support Monochrome LCD
Light Source Halogen
Illumination Method Fiber-optic
Rated Voltage 5V DC
Rated Current 1A
Power Rating 5W
Warm-Up Time Instant
Duty Cycle Continuous
Weight 0.09 kg (0.19 lbs)

Engineering Advantages

  • Instant Illumination Restoration: The 2711-NL1 eliminates warm-up delays common in older lighting technologies. The halogen source provides full rated brightness the moment the terminal initiates power.

  • Seamless Terminal Integration: This field-replaceable unit features a plug-in electrical interface. This design allows maintenance personnel to swap the backlight without unsoldering components or removing the entire HMI from the cabinet door.

  • Fiber-Optic Light Distribution: The integrated fiber-optic assembly channels light evenly across the monochrome display. This prevents "hot spots" or uneven shadowing, ensuring operators can read critical alarm data from various viewing angles.

  • Terminal-Controlled Dimming: The hardware supports native dimming commands from the PanelView terminal. This allows the system to reduce brightness during inactive periods, effectively extending the lamp's service life and reducing power consumption.

  • Rugged Continuous Duty Cycle: Engineered for 24/7 industrial operations, the 2711-NL1 maintains consistent light output under continuous duty, preventing unexpected display blackouts during production shifts.

Maintenance & Installation Tips

  1. Safety First: Disconnect all power from the PanelView 550 terminal before attempting a backlight replacement to avoid electrical shock or damage to the HMI motherboard.

  2. Clean Handling: Avoid touching the halogen bulb surface with bare fingers. Skin oils can create localized heat concentrations that significantly shorten the lifespan of the lamp. Use clean gloves or a lint-free cloth.

  3. Alignment: Ensure the fiber-optic assembly seats fully into the display housing. Proper alignment maximizes light transfer and prevents internal glare within the bezel.

FAQs

Q: How do I know if my PanelView 550 requires a 2711-NL1?

A: If the terminal powers on and responds to touch/key commands but the screen remains dark or extremely dim, the backlight has likely reached the end of its life. The 2711-NL1 serves as the direct fix for this hardware failure.

Q: Does this backlight support the Color PanelView 550 terminals?

A: No. The 2711-NL1 specifically supports Monochrome LCD versions of the PanelView 550. Color terminals typically utilize different lighting technologies or CCFL tubes.

Q: Can I adjust the brightness of the new lamp?

A: Yes. The 2711-NL1 supports terminal-controlled dimming. You can adjust the intensity through the PanelView’s system configuration menu or via the application software to suit your ambient lighting conditions.

Q: Is this an LED upgrade or a standard halogen replacement?

A: This is the 100% Brand New original halogen-based assembly. It maintains the exact technical profile and fiber-optic compatibility of the factory-installed part to ensure 100% hardware compliance.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Manufacturing Execution Systems serve as the digital backbone of modern factory floors. Positioned at Level 3 of the ISA-95 automation pyramid, MES links enterprise resource planning with real-time shop floor control systems. Today, industrial operators rely on MES software to bridge operational strategy with physical production execution.

Read more
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more
Hot Standby vs. Cold Standby Redundancy in Industrial Automation

Hot Standby vs. Cold Standby Redundancy in Industrial Automation

System availability determines process safety and productivity in industrial automation. Control engineers deploy redundancy to eliminate single points of failure. This technical guide evaluates Hot Standby vs. Cold Standby architectures, comparing failover speeds, memory sync, cost trade-offs, and field selection criteria.

Read more