PRODUCT SKU : 1797-IRT8

PRODUCT TYPE : I/O Modules

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen-Bradley 1797-IRT8 is a high-performance, 8-channel temperature input module designed for the FLEX Ex I/O platform. This module provides a specialized interface for connecting Resistance Temperature Detectors (RTDs) and thermocouples in hazardous area applications. It is engineered to reside on the internal bus and offers configurable signal conditioning for precise thermal monitoring.

The 1797-IRT8 is primarily utilized in intrinsically safe environments where explosive atmospheres are a concern. By integrating high-density analog inputs into a compact form factor, it allows for efficient data acquisition from sensors such as Pt100, Ni, and various thermocouple types (J, K, T, E, R, S, B, N, C, and L).

Technical Specifications

Feature Specification
Manufacturer Allen-Bradley / Rockwell Automation
Product Series FLEX Ex 1797
Module Type Temperature Input (RTD / Thermocouple)
Number of Inputs 8 Isolated Channels
Input Signal Range -40 to 100 mV
Resolution 16-bit
Settling Time 8 milliseconds
Power Supply 9.5V DC
Field-side Power Consumption 1.6 Watts
Power Dissipation 1.6 Watts maximum
Thermal Dissipation 5.46 BTU/hr
Weight 0.31 kg (0.69 lbs)

Functional Characteristics

The 1797-IRT8 features advanced internal bus configuration, allowing engineers to define input types per channel. The module includes integrated lead resistance compensation to maintain signal integrity over long cable runs, ensuring that resistance variations do not skew temperature readings.

Designed for reliability in demanding industrial sectors—including oil and gas, chemical processing, and pharmaceutical manufacturing—the module supports the intrinsically safe standards required for Zone 1 and Zone 2 deployments when used with appropriate FLEX Ex backplanes and barriers.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more