Skip to content

What are you looking for?


You may also like

1794-IF8IHNFXT | Allen Bradley | Flex I/O 8-Channel Isolated Analog Input Module1794-IF8IHNFXT | Allen Bradley | Flex I/O 8-Channel Isolated Analog Input Module1794-IF8IHNFXT | Allen Bradley | Flex I/O 8-Channel Isolated Analog Input Module
1794-IF8IHNFXT | Allen Bradley | Flex I/O 8-Channel Isolated Analog Input Module
1794-IF8IHNFXT | Allen Bradley | Flex I/O 8-Channel Isolated Analog Input Module
1794-IF8IHNFXT | Allen Bradley | Flex I/O 8-Channel Isolated Analog Input Module

1794-IF8IHNFXT | Allen Bradley | Flex I/O 8-Channel Isolated Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1794-IF8IHNFXT

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 1794-IF8IHNFXT provides high-density, isolated analog signal processing for the FLEX™ I/O platform. This 8-channel module captures precise current signals (0–20mA) from field transmitters and sensors, utilizing Sigma-Delta conversion to ensure superior data accuracy. As an "XT" (Extended Temperature) and "HN" (HART-capable) designated module, it thrives in harsh industrial environments while allowing for advanced instrument diagnostics. We supply this unit in 100% Brand New and Original condition, specifically designed for process control applications requiring high channel-to-channel isolation and ruggedized performance.

Technical Specifications

The 1794-IF8IHNFXT delivers advanced signal conditioning via the following technical parameters:

Feature Specification
Manufacturer Allen Bradley (Rockwell Automation)
Number of Channels 8 Single-ended Isolated Inputs
Input Current Range 0 to 20 milliamperes
Conversion Type Sigma Delta
Data Formats RAW/Proportional, Engineering Units, Percent of Full Scale
Power Supply Voltage 24V DC (19.2 to 31.2V DC Range)
Flexbus Current 80 mA @ 5V DC
Input Resistance 249 ohms
Max Power Dissipation 4.8 Watts @ 31.2V DC
Status Indicators 1 Red/Green LED indicator
Enclosure Style Open-style (IP20 when mounted)

Engineering Advantages

The 1794-IF8IHNFXT addresses critical challenges in modern process automation:

  • Channel-to-Channel Isolation: High-performance isolation circuitry prevents ground loops and eliminates noise transfer between channels. This feature protects your central controller from field-side transients and ensures that a fault on one instrument does not compromise the data integrity of the other seven channels.

  • Advanced HART Integration: The "HN" designation supports HART (Highway Addressable Remote Transducer) protocol communication. This allows the control system to access secondary process variables and device diagnostics from "smart" field instruments without requiring additional handheld communicators or specialized wiring.

  • Superior XT Thermal Profile: Engineered for "Extreme" conditions, the XT-series components withstand a broader temperature spectrum than standard I/O. This makes the 1794-IF8IHNFXT ideal for remote terminal units (RTUs) or outdoor cabinets where internal temperatures fluctuate significantly.

  • Flexible Data Scaling: The module performs internal scaling into engineering units or percentage of full scale. This offloads calculation tasks from the PLC processor, simplifying logic programming and providing a more intuitive interface for operators monitoring raw sensor data.

  • Noise Immunity with Sigma-Delta Conversion: The Sigma-Delta conversion technique oversamples the input signal, effectively filtering out high-frequency industrial noise. When paired with shielded copper wire, the module provides a rock-solid signal path even in high-EMI environments near variable frequency drives (VFDs).

FAQs

  • Does the 1794-IF8IHNFXT support HART pass-through?

    Yes. When used with a compatible HART-capable adapter (such as the 1794-AENTR), this module allows Asset Management Software (AMS) to communicate directly with field instruments for remote calibration and health monitoring.

  • Can I use this module for 4–20mA signals?

    Absolutely. While the technical range is 0–20mA, you simply configure the software scaling to recognize 4mA as your 0% point and 20mA as your 100% point.

  • What type of wiring does this module require?

    To maintain the specified accuracy and noise rejection, always use shielded copper wire. Ensure the shield is grounded at only one end to prevent ground loops that could interfere with the Sigma-Delta conversion.

  • Is this a genuine, factory-sealed Allen Bradley unit?

    We guarantee every 1794-IF8IHNFXT is 100% Brand New and Original. It ships in the original factory box with authentic UPC (885630333571) and manufacturer-applied quality control seals intact.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems

Understanding Marshalling Cabinets in Industrial Control Systems

In large-scale industrial automation projects, managing thousands of field signals is a massive logistical challenge. The Marshalling Cabinet serves as the critical organizational hub that bridges the gap between rugged field wiring and sensitive control room electronics.

Read more
Exploring the DDE Protocol in Modern Industrial Automation

Exploring the DDE Protocol in Modern Industrial Automation

In the specialized world of industrial automation, moving data between software applications is a fundamental requirement. One of the earliest methods to achieve this was the Dynamic Data Exchange (DDE) protocol. While newer standards exist today, DDE remains a cornerstone of legacy systems and specific integration tasks.

Read more
Understanding SCADA vs. HMI: A Technical Guide for Industrial Automation

Understanding SCADA vs. HMI: A Technical Guide for Industrial Automation

In the world of factory automation, professionals often use the terms HMI and SCADA interchangeably. However, these systems serve distinct roles within a control hierarchy. Understanding their unique functions is vital for designing efficient industrial automation architectures.

Read more