Product Description

The Allen Bradley 1794-IA16 is a FLEX I/O AC digital input module designed to handle 16 non-isolated input channels. It converts AC signals into logic-level inputs for distributed control systems. With DIN rail mounting, multiple terminal base compatibility, and integrated LED indicators for each channel, this module provides reliable input monitoring in industrial automation environments.

Technical Specifications

  • Manufacturer Allen Bradley

  • Product Line FLEX I/O 1794

  • Product Type AC Digital Input Module

  • Part Number 1794-IA16

  • Weight 0.25 lbs (0.11 kg)

  • Inputs 16 non-isolated channels

  • Terminal Base Compatibility 1794-TB3, 1794-TB3S, 1794-TBN, 1794-TB3K, 1794-TB3SK, 1794-TBNK

  • Keyswitch Position 8

  • On-State Voltage Range 74–132 V AC

  • Off-State Voltage (Max) 20 V AC

  • On-State Current Min 5.49 mA, Max 14.81 mA

  • Off-State Current Min 2.9 mA

  • Nominal Input Current 12 mA @ 120 V AC

  • Flexbus Current 20 mA

  • Power Dissipation 6.4 W @ 132 V AC max

  • Indicators 16 yellow LED status indicators

  • Mounting Style DIN rail

  • Enclosure Type Open-style (no housing)

  • Wire Size Determined by installed terminal base (22–14 AWG typical)

  • Operating Temperature 0–55 °C (32–131 °F)

  • Storage Temperature –40–85 °C (–40–185 °F)

  • Vibration Resistance 5 g @ 10–500 Hz

  • Shock Resistance 30 g

Application Scenarios

  • Monitoring AC input signals in distributed FLEX I/O systems

  • Industrial automation requiring multiple input channels with LED diagnostics

  • Control panels where compact DIN rail modules are preferred

FAQ

Q: How many input channels does the 1794-IA16 provide?  A: It supports 16 non-isolated AC input channels.

Q: What voltage range is supported for ON-state detection?  A: Between 74 V AC and 132 V AC.

Q: Does the module provide input status indication?  A: Yes, each channel has a yellow LED indicator.

Comparable Models

  • 1794-IA16: 16-point AC input module (this model)

  • 1794-IB16: 16-point DC input module

  • 1794-IV16: 16-point DC voltage input module

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Variable Frequency Drives (VFDs) play a crucial role in modern industrial automation by controlling motor speed, torque, and acceleration. However, high-inertia loads and vertical lifting systems require precise mechanical braking logic to ensure operational safety and prevent equipment damage.

Read more
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more