Only 10 left - Selling fast

PRODUCT SKU : 1756-RM2XT

PRODUCT TYPE : Redundancy Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The 1756-RM2XT provides high-speed data synchronization between primary and secondary chassis in a ControlLogix redundancy system. As an "XT" (Extended Temperature) module, it features specialized components to withstand harsher environmental conditions than standard automation hardware. This module ensures bumpless switchover during a controller or chassis failure, maintaining continuous process operation in mission-critical applications. We supply this unit as 100% Brand New original hardware, ensuring your high-availability architecture operates with factory-certified precision and thermal resilience.

Technical Specifications

The 1756-RM2XT utilizes advanced fiber optic technology to maintain real-time chassis synchronization:

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Module Type Enhanced Redundancy Module (XT Series)
Fiber Optic Support Single-channel (1)
Max Cable Length 4 Kilometers
Wavelength 1300 nm
Transmission Speed 1000 Mbps (1 Gbps)
Operating Temp -25°C to +70°C (-13°F to +158°F)*
Dimensions 5.51 x 4.41 x 5.71 inches
Weight 0.29 kg (0.64 lb)
Wire Size 20 AWG (for grounding)

Note: While standard specs list 0-60°C, the XT designation officially supports expanded ranges up to 70°C when installed in appropriate XT chassis.

Engineering Advantages

  • Long-Distance Synchronization: The 1300 nm fiber optic interface supports cable runs up to 4 kilometers. This allows engineers to physically separate redundant chassis in different fire zones or remote control rooms to protect against localized disasters.

  • Bumpless Switchover Performance: The 1000 Mbps (1 Gbps) transmission speed ensures near-instantaneous data mirroring. During a fault, the 1756-RM2XT facilitates a switchover so fast that the field actuators and remote I/O perceive no interruption in the control logic.

  • Extended Thermal Durability: The XT-series construction utilizes robust internal components and superior heat dissipation designs. This solves the pain point of hardware failure in non-climate-controlled cabinets or extreme outdoor environments.

  • Fiber Optic Isolation: By using fiber optics for chassis synchronization, the module provides total electrical isolation between redundant pairs. This eliminates ground loops and protects the control system from high-voltage surges or electromagnetic interference (EMI).

  • Simplified Redundancy Setup: The module handles complex synchronization tasks automatically. Once connected via fiber, it manages the scan list and data table mirroring without requiring manual code-heavy synchronization routines from the programmer.

FAQs

Q: Can I use the 1756-RM2XT with a standard 1756-RM2 module?

A: No. For a redundant pair to function correctly, both modules must share the same hardware series and firmware revision. We recommend using two 1756-RM2XT modules to ensure consistent thermal performance and synchronization timing.

Q: What type of fiber optic cable does this module require?

A: The 1756-RM2XT requires 62.5/125 micron multi-mode fiber optic cable. Ensure you use high-quality LC-style connectors to maintain the 1000 Mbps transmission integrity over long distances.

Q: Does this module require a separate power supply?

A: No. The 1756-RM2XT draws its power directly from the ControlLogix backplane. However, you must ensure the chassis power supply (such as a 1756-PA75R) provides sufficient current for the entire redundancy set.

Q: Why should I choose the "XT" version over the standard 1756-RM2?

A: Choose the 1756-RM2XT if your installation site experiences temperatures outside the standard 0-60°C range. The XT version specifically targets applications in oil and gas, mining, and remote pumping stations where environmental control is limited.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more