PRODUCT SKU : 1756-IRT8I

PRODUCT TYPE : Isolated Analog I/O Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1756-IRT8I is an 8-channel ControlLogix isolated analog input module optimized for precise temperature and millivolt (mV) measurements. Designed for thermocouple applications, it offers high-resolution signal acquisition and maintains full electrical isolation between input channels and the backplane.

Technical Specifications

  • Manufacturer: Allen-Bradley (Rockwell Automation)

  • Model / Part Number: 1756-IRT8I

  • Product Type: ControlLogix Isolated Analog I/O Module

  • Channels: 8 isolated inputs

  • Input Mode: Thermocouple

  • Input Voltage Range: -100 to 100 mV

  • Actual Input Range Capability: -101 to 101 mV

  • Resolution: 24-bit theoretical, 23.98-bit effective across full range

  • Removable Terminal Block: 36-pin (compatible with 1756-TBCH or 1756-TBS6H)

  • Isolation: Each input channel is individually isolated to prevent interference

  • Module Mounting: Standard ControlLogix chassis slot

Key Features

  • High-accuracy 8-channel analog input for thermocouples

  • Individually isolated channels improve system safety and signal integrity

  • Compatible with standard ControlLogix terminal blocks for easy installation

  • Supports millivolt-range signals for precise process monitoring

  • Ideal for temperature and low-voltage sensor integration

Applications

  • Industrial process temperature measurement and monitoring

  • Integration with ControlLogix systems requiring isolated analog inputs

  • High-precision signal acquisition for research or manufacturing processes

FAQs

Q1: What type of signals does the 1756-IRT8I accept?
It supports thermocouple temperature signals and low-voltage millivolt inputs.

Q2: How many inputs are isolated?
All 8 channels are individually isolated for improved safety and reduced cross-talk.

Q3: Which terminal blocks are compatible?
It is compatible with 36-pin 1756-TBCH or 1756-TBS6H removable terminal blocks.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Dry Contacts in PLC Wiring: An Industrial Automation Guide

Understanding Dry Contacts in PLC Wiring: An Industrial Automation Guide

Mastering contact switching principles is essential for reliable control panels. Field devices and PLCs interface through dry or wet contacts. This technical guide examines the mechanics of dry contacts, explores their wiring architectures, and evaluates their key advantages in industrial automation.

Read more
Ultimate Commissioning Checklist for Industrial Automation Systems: An Engineering Guide

Ultimate Commissioning Checklist for Industrial Automation Systems: An Engineering Guide

Commissioning is the most decisive phase of an industrial automation project, transforming control hardware and software into an operational facility. Thorough testing prevents costly startup delays and builds customer confidence. This guide covers essential checklists, electrical standards, and best practices.

Read more
Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Unplanned downtime poses a major financial threat to process manufacturing. To prevent costly interruptions, engineers deploy redundant PLC and DCS architectures that ensure continuous operation when hardware fails. This technical guide explores redundancy principles, critical system nodes, and real-world scenarios.

Read more