Skip to content

What are you looking for?


You may also like

1756-IRT8I | Allen-Bradley ControlLogix Isolated Analog I/O Module1756-IRT8I | Allen-Bradley ControlLogix Isolated Analog I/O Module1756-IRT8I | Allen-Bradley ControlLogix Isolated Analog I/O Module
1756-IRT8I | Allen-Bradley ControlLogix Isolated Analog I/O Module
1756-IRT8I | Allen-Bradley ControlLogix Isolated Analog I/O Module
1756-IRT8I | Allen-Bradley ControlLogix Isolated Analog I/O Module

1756-IRT8I | Allen-Bradley ControlLogix Isolated Analog I/O Module


Only 10 left - Selling fast

PRODUCT SKU : 1756-IRT8I

PRODUCT TYPE : Isolated Analog I/O Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1756-IRT8I is an 8-channel ControlLogix isolated analog input module optimized for precise temperature and millivolt (mV) measurements. Designed for thermocouple applications, it offers high-resolution signal acquisition and maintains full electrical isolation between input channels and the backplane.

Technical Specifications

  • Manufacturer: Allen-Bradley (Rockwell Automation)

  • Model / Part Number: 1756-IRT8I

  • Product Type: ControlLogix Isolated Analog I/O Module

  • Channels: 8 isolated inputs

  • Input Mode: Thermocouple

  • Input Voltage Range: -100 to 100 mV

  • Actual Input Range Capability: -101 to 101 mV

  • Resolution: 24-bit theoretical, 23.98-bit effective across full range

  • Removable Terminal Block: 36-pin (compatible with 1756-TBCH or 1756-TBS6H)

  • Isolation: Each input channel is individually isolated to prevent interference

  • Module Mounting: Standard ControlLogix chassis slot

Key Features

  • High-accuracy 8-channel analog input for thermocouples

  • Individually isolated channels improve system safety and signal integrity

  • Compatible with standard ControlLogix terminal blocks for easy installation

  • Supports millivolt-range signals for precise process monitoring

  • Ideal for temperature and low-voltage sensor integration

Applications

  • Industrial process temperature measurement and monitoring

  • Integration with ControlLogix systems requiring isolated analog inputs

  • High-precision signal acquisition for research or manufacturing processes

FAQs

Q1: What type of signals does the 1756-IRT8I accept?
It supports thermocouple temperature signals and low-voltage millivolt inputs.

Q2: How many inputs are isolated?
All 8 channels are individually isolated for improved safety and reduced cross-talk.

Q3: Which terminal blocks are compatible?
It is compatible with 36-pin 1756-TBCH or 1756-TBS6H removable terminal blocks.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Industrial automation engineers frequently encounter liquid level regulation challenges across diverse process plants. Traditional ON-OFF control mechanisms often disrupt system stability due to abrupt actuator switching. Therefore, upgrading to closed-loop architectures like proportional control yields smoother responses. In a typical PLC environment, such as Siemens TIA Portal, engineers utilize closed-loop feedback to minimize process errors without requiring full PID complexity.

Read more
Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

In industrial automation, programmable logic controllers (PLCs) serve as the core intelligence of modern factory automation and distributed control systems (DCS). Understanding how a PLC transitions between modes is vital for maintenance engineers. Typically, a PLC operates across four primary modes: Run, Stop, Start-Up, and Hold. When power is applied, the system immediately boots into Stop mode before initiating the Start-Up sequence. If the controller encounters a critical error during execution, it automatically reverts to Stop mode to prevent equipment damage. Therefore, monitoring these state transitions helps technicians maintain high system availability.

Read more
Comprehensive Guide to Servo Motor Drive Control Techniques in Industrial Automation

Comprehensive Guide to Servo Motor Drive Control Techniques in Industrial Automation

Precision motion control systems drive high-throughput manufacturing across modern industrial automation environments. Unlike standard induction motors running on basic variable frequency drives, servo motor systems deliver sub-millimeter positioning accuracy and fast dynamic response.

Read more