Overview

The Allen-Bradley 1756-IRT8I is an 8-channel ControlLogix isolated analog input module optimized for precise temperature and millivolt (mV) measurements. Designed for thermocouple applications, it offers high-resolution signal acquisition and maintains full electrical isolation between input channels and the backplane.

Technical Specifications

  • Manufacturer: Allen-Bradley (Rockwell Automation)

  • Model / Part Number: 1756-IRT8I

  • Product Type: ControlLogix Isolated Analog I/O Module

  • Channels: 8 isolated inputs

  • Input Mode: Thermocouple

  • Input Voltage Range: -100 to 100 mV

  • Actual Input Range Capability: -101 to 101 mV

  • Resolution: 24-bit theoretical, 23.98-bit effective across full range

  • Removable Terminal Block: 36-pin (compatible with 1756-TBCH or 1756-TBS6H)

  • Isolation: Each input channel is individually isolated to prevent interference

  • Module Mounting: Standard ControlLogix chassis slot

Key Features

  • High-accuracy 8-channel analog input for thermocouples

  • Individually isolated channels improve system safety and signal integrity

  • Compatible with standard ControlLogix terminal blocks for easy installation

  • Supports millivolt-range signals for precise process monitoring

  • Ideal for temperature and low-voltage sensor integration

Applications

  • Industrial process temperature measurement and monitoring

  • Integration with ControlLogix systems requiring isolated analog inputs

  • High-precision signal acquisition for research or manufacturing processes

FAQs

Q1: What type of signals does the 1756-IRT8I accept?
It supports thermocouple temperature signals and low-voltage millivolt inputs.

Q2: How many inputs are isolated?
All 8 channels are individually isolated for improved safety and reduced cross-talk.

Q3: Which terminal blocks are compatible?
It is compatible with 36-pin 1756-TBCH or 1756-TBS6H removable terminal blocks.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more