Skip to content

What are you looking for?


You may also like

1756-IRT8I | Allen-Bradley ControlLogix Isolated Analog I/O Module1756-IRT8I | Allen-Bradley ControlLogix Isolated Analog I/O Module1756-IRT8I | Allen-Bradley ControlLogix Isolated Analog I/O Module
1756-IRT8I | Allen-Bradley ControlLogix Isolated Analog I/O Module
1756-IRT8I | Allen-Bradley ControlLogix Isolated Analog I/O Module
1756-IRT8I | Allen-Bradley ControlLogix Isolated Analog I/O Module

1756-IRT8I | Allen-Bradley ControlLogix Isolated Analog I/O Module


Only 10 left - Selling fast

PRODUCT SKU : 1756-IRT8I

PRODUCT TYPE : Isolated Analog I/O Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1756-IRT8I is an 8-channel ControlLogix isolated analog input module optimized for precise temperature and millivolt (mV) measurements. Designed for thermocouple applications, it offers high-resolution signal acquisition and maintains full electrical isolation between input channels and the backplane.

Technical Specifications

  • Manufacturer: Allen-Bradley (Rockwell Automation)

  • Model / Part Number: 1756-IRT8I

  • Product Type: ControlLogix Isolated Analog I/O Module

  • Channels: 8 isolated inputs

  • Input Mode: Thermocouple

  • Input Voltage Range: -100 to 100 mV

  • Actual Input Range Capability: -101 to 101 mV

  • Resolution: 24-bit theoretical, 23.98-bit effective across full range

  • Removable Terminal Block: 36-pin (compatible with 1756-TBCH or 1756-TBS6H)

  • Isolation: Each input channel is individually isolated to prevent interference

  • Module Mounting: Standard ControlLogix chassis slot

Key Features

  • High-accuracy 8-channel analog input for thermocouples

  • Individually isolated channels improve system safety and signal integrity

  • Compatible with standard ControlLogix terminal blocks for easy installation

  • Supports millivolt-range signals for precise process monitoring

  • Ideal for temperature and low-voltage sensor integration

Applications

  • Industrial process temperature measurement and monitoring

  • Integration with ControlLogix systems requiring isolated analog inputs

  • High-precision signal acquisition for research or manufacturing processes

FAQs

Q1: What type of signals does the 1756-IRT8I accept?
It supports thermocouple temperature signals and low-voltage millivolt inputs.

Q2: How many inputs are isolated?
All 8 channels are individually isolated for improved safety and reduced cross-talk.

Q3: Which terminal blocks are compatible?
It is compatible with 36-pin 1756-TBCH or 1756-TBS6H removable terminal blocks.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the Right Cables for Industrial Automation: A Comprehensive Guide

Selecting the appropriate cabling infrastructure is critical for the success of any industrial automation project. Improper cable selection often leads to signal degradation, system instability, and costly downtime. As an automation engineer, I frequently see projects compromised by poor cabling choices in harsh industrial environments. This guide simplifies the complex landscape of cabling to help you make informed decisions for your PLC, DCS, and control systems.

Read more
Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

Preventing Spurious Trips in Emergency Stop Systems: A Technical Guide

In industrial automation, the Emergency Stop (E-Stop) pushbutton is the ultimate safety line. However, relying on a single Normally-Closed (NC) contact can sometimes lead to unexpected spurious trips. As a control systems engineer, I have seen these nuisance trips halt entire production lines, causing significant downtime. Understanding why these components fail and how to implement robust architecture is essential for any reliable DCS or PLC-based safety system.

Read more
Sequencing Induction Motor Control with PLC Logic: Best Practices

Sequencing Induction Motor Control with PLC Logic: Best Practices

In modern industrial automation, controlling a group of induction motors requires precision and safety. Uncontrolled simultaneous startup of multiple large motors often causes significant voltage dips, potentially triggering protective trips. Therefore, implementing a sequential startup and shutdown strategy is essential. This approach minimizes inrush current and ensures the system operates within established power constraints. A robust PLC program serves as the ideal engine for orchestrating these sequences.

Read more