PRODUCT SKU : 1756-IG16

PRODUCT TYPE : Backup Communication Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1756-IG16 is a 16-point digital input module designed for ControlLogix systems. This module operates at a 5V DC input with a TTL source and features fast input delay times, low power dissipation, and reliable performance. The 1756-IG16 is ideal for industrial automation systems that require fast and efficient digital input processing.

Key Features

• Module Type: Digital DC Input Module
• Inputs: 16 points (9 per common)
• Input Voltage: 5V DC with TTL source
• Operating Voltage Range: 4.5V to 5.5V DC
• Input Delay Time: 0.25 milliseconds, plus selected filter time
• Off-State Current: 4.1 milliamps (maximum)
• Power Dissipation: 1.4 Watts at 60°C (maximum)
• Backplane Current at 5V: 110 milliamps
• Weight: 0.69 lbs (0.31 kg)
• Product Line: ControlLogix
• Dimensions: Compact design suitable for space-constrained installations

Technical Specifications

• Manufacturer: Allen-Bradley
• Product Number: 1756-IG16
• Module Type: Digital Input Module
• Inputs: 16 points (9 per common)
• Voltage: 5V DC with TTL Source
• Operating Voltage Range: 4.5V to 5.5V DC
• Input Delay Time: 0.25ms plus selected filter time
• Maximum Off-State Input Current: 4.1mA
• Power Dissipation: 1.4W at 60°C (max.)
• Backplane Current: 110mA at 5V DC
• Weight: 0.69 lbs (0.31 kg)
• Module Compatibility: Compatible with ControlLogix systems

Applications

The 1756-IG16 digital input module is perfect for industrial control and automation applications where fast and reliable digital input processing is required. Key industries include:
• Manufacturing Automation: Suitable for use in automated production lines, machine controls, and process monitoring
• Process Control: Ideal for systems that require quick response times for various inputs
• Energy Management Systems: Provides efficient digital input processing for energy control systems
• Building Automation: Ensures smooth data flow between devices in automated building systems

Advantages

• Fast Input Processing: 0.25ms input delay ensures fast response times
• Low Power Consumption: Low power dissipation (1.4W max) for energy-efficient operations
• Wide Voltage Range: Supports operating voltages from 4.5V to 5.5V DC
• Reliable Performance: Excellent for continuous use in demanding industrial environments
• Compact and Lightweight: Weighs just 0.69 lbs (0.31 kg), perfect for space-limited installations

FAQ

Q1: What is the input voltage range for the 1756-IG16 module?
A1: The 1756-IG16 operates within a voltage range of 4.5V to 5.5V DC, with a 5V DC TTL source.

Q2: How many input points does the 1756-IG16 module have?
A2: The 1756-IG16 has 16 input points, with 9 points per common.

Q3: Can this module be used with other systems apart from ControlLogix?
A3: No, the 1756-IG16 module is specifically designed for use with ControlLogix systems.

Q4: What is the input delay time for the 1756-IG16 module?
A4: The input delay time is 0.25 milliseconds, plus the selected filter time for additional precision.

Q5: What is the maximum power dissipation of the 1756-IG16?
A5: The 1756-IG16 has a maximum power dissipation of 1.4 Watts at 60°C.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Variable Frequency Drives (VFDs) play a crucial role in modern industrial automation by controlling motor speed, torque, and acceleration. However, high-inertia loads and vertical lifting systems require precise mechanical braking logic to ensure operational safety and prevent equipment damage.

Read more
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more