PRODUCT SKU : 1738-ACNR

PRODUCT TYPE : ControlNet Network Adapter

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen-Bradley 1738-ACNR ArmorPoint adapter module provides ControlNet communication capability for distributed I/O systems. Designed for rugged environments, it supports high-speed data transfer, robust power handling, and IP-rated protection for field installations. With integrated overvoltage protection and wide operating temperature tolerance, it ensures reliable performance in demanding industrial applications.

Technical Specifications

  • Manufacturer Allen-Bradley

  • Product Line ArmorPoint Modules

  • Product Type ControlNet Network Adapter

  • Part Number 1738-ACNR

  • Weight 0.81 lbs (0.37 kg)

  • Communication Rate 5 Mbps (ControlNet)

  • Input Voltage Rating 24 VDC nominal; operating range 10–28.8 VDC

  • Inrush Current 6 A maximum for 10 ms

  • Field Side Power Requirements 24 VDC at 425 mA (maximum)

  • Maximum Power Consumption 10.2 W at 28.8 VDC

  • Maximum Power Dissipation 5.0 W at 28.8 VDC

  • Thermal Dissipation 16.9 BTU/hr at 28.8 VDC

  • Input Protection Reverse polarity protected

  • Isolation Voltage 50 V continuous

  • Electromagnetic Emissions Group 1, Class A

  • Enclosure Rating IP65, IP66, IP67 (when properly marked)

  • Operating Temperature Range -4 to 140 °F (-20 to 60 °C)

  • Storage Temperature Range -40 to 185 °F (-40 to 85 °C)

Application Scenarios

  • Distributed I/O systems requiring ControlNet communication

  • Harsh industrial environments needing IP65/66/67-rated modules

  • Applications requiring reliable power handling and thermal dissipation

  • Systems needing reverse polarity protection for field wiring

FAQ

Q: What communication speed does the 1738-ACNR support?  A: It supports ControlNet communication at 5 Mbps.

Q: Is the module suitable for outdoor or harsh environments?  A: Yes, it meets IP65/66/67 ratings when properly marked.

Q: What type of input protection is included?  A: Reverse polarity protection is integrated.

Comparison with Similar Models

  • 1738-ADN: DeviceNet adapter for ArmorPoint modules.

  • 1738-AENTR: Ethernet/IP adapter with dual ports.

  • 1738-ACNR: ControlNet adapter optimized for high-speed communication.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more
Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Industrial automation relies on continuous operational stability to prevent catastrophic downtime and financial loss. While standard dictionary definitions treat redundancy as superfluous, industrial engineers consider redundant control architectures indispensable for high-availability systems. Implementing backup hardware ensures seamless takeover during primary equipment failures, protecting critical infrastructure across manufacturing and process industries.

Read more