Skip to content

What are you looking for?


You may also like

170ADI34000 | Schneider Modicon Momentum | Discrete Input Module 16-Channel 24V DC170ADI34000 | Schneider Modicon Momentum | Discrete Input Module 16-Channel 24V DC170ADI34000 | Schneider Modicon Momentum | Discrete Input Module 16-Channel 24V DC
170ADI34000 | Schneider Modicon Momentum | Discrete Input Module 16-Channel 24V DC
170ADI34000 | Schneider Modicon Momentum | Discrete Input Module 16-Channel 24V DC
170ADI34000 | Schneider Modicon Momentum | Discrete Input Module 16-Channel 24V DC

170ADI34000 | Schneider Modicon Momentum | Discrete Input Module 16-Channel 24V DC


Only 10 left - Selling fast

PRODUCT SKU : 170ADI34000

PRODUCT TYPE : Discrete Input Module

PRODUCT VENDOR : Schneider


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The 170ADI34000 is a high-reliability discrete input module designed for the Modicon Momentum automation platform. It provides 16 positive logic DC input channels in a single group, enabling precise monitoring of field signals. This module is engineered for industrial environments with full isolation between channels and the bus, and visual LED indicators for real-time status monitoring.

Technical Specifications

  • Model + Part Number: 170ADI34000

  • Manufacturer: Schneider Electric

  • Type: Discrete Input Module

  • Series: Modicon Momentum

  • Discrete Input Number: 16

  • Group of Channels: 1 group of 16 inputs

  • Input Logic: Positive

  • Voltage Range: -3…30 V DC

  • Isolation: 500 V AC between channels and bus

  • Local Signalling: 16 LEDs for channel status

  • Dimensions: Height 141.5 mm, Width 125 mm, Depth 47.5 mm

  • Weight: 0.19 kg (0.42 lb)

  • Environment: Protective TC treatment

Terminals Configuration

  • (1)IN_DIS#1, (2)IN_DIS#2, (3)IN_DIS#3, (4)IN_DIS#4, (5)IN_DIS#5

  • (6)IN_DIS#6, (7)IN_DIS#7, (8)IN_DIS#8, (9)IN_DIS#9, (10)IN_DIS#10

  • (11)IN_DIS#11, (12)IN_DIS#12, (13)IN_DIS#13, (14)IN_DIS#14, (15)IN_DIS#15, (16)IN_DIS#16

  • Power Terminals: (L+)PW_POS, (M-)PW_NEG

Ordering & Packaging

  • Category: US1PC3118206

  • Returnable: Yes

  • Unit Package 1: 1 PCE, 388 g, 5.7 × 18.2 × 26.0 cm

  • Unit Package 2: 10 units, 4.321 kg, 30 × 30 × 40 cm

  • Warranty: 18 months

Applications
Suitable for monitoring discrete field signals in industrial processes, factory automation, and control systems requiring 24 V DC inputs with high channel isolation and clear status indication.

FAQ
Q: How are the inputs isolated?
A: Each channel is isolated from the bus at 500 V AC, ensuring safe signal separation.
Q: Can this module display input status locally?
A: Yes, it features 16 LEDs corresponding to each input channel.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more