Skip to content

What are you looking for?


You may also like

Schneider Electric Modicon Quantum 140DDI35300 24V DC Discrete Input ModuleSchneider Electric Modicon Quantum 140DDI35300 24V DC Discrete Input ModuleSchneider Electric Modicon Quantum 140DDI35300 24V DC Discrete Input Module
Schneider Electric Modicon Quantum 140DDI35300 24V DC Discrete Input Module
Schneider Electric Modicon Quantum 140DDI35300 24V DC Discrete Input Module
Schneider Electric Modicon Quantum 140DDI35300 24V DC Discrete Input Module

Schneider Electric Modicon Quantum 140DDI35300 24V DC Discrete Input Module


Only 10 left - Selling fast

PRODUCT SKU : 140DDI35300

PRODUCT TYPE : Discrete Input Module

PRODUCT VENDOR : Schneider


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Schneider Electric 140DDI35300 serves as a high-density discrete input gateway for the Modicon Quantum automation platform. This module provides 32 individual channels designed to monitor low-voltage 24V DC signals from field devices such as pushbuttons, limit switches, and proximity sensors. Operating on a positive (sink) logic architecture, it translates physical plant states into digital data for the Quantum CPU. We supply this module as 100% brand new original equipment, ensuring full compatibility with existing Quantum backplanes and mission-critical control architectures.

Technical Specifications

The 140DDI35300 utilizes high-speed circuitry to deliver rapid signal acquisition across four distinct groups of channels.

  • Discrete Input Number: 32 Channels

  • Group Configuration: 4 groups of 8 channels

  • Logic Input: Positive (Sink)

  • Rated Voltage: 24 V DC

  • Input Voltage Limits: 19.2 to 30 V DC

  • Response Time: <= 1 ms (State 0 to 1 and 1 to 0)

  • Input Impedance: 2500 Ohm

  • Isolation: 1780 Vrms for 1 minute (between group and bus)

  • Bus Current Requirement: 330 mA

  • Addressing Requirement: 2 input words

  • Power Dissipation: 1.7 W + (0.36 x number of active points)

  • Weight: 0.7 lb (0.3 kg)

Engineering Advantages

  • Ultra-Fast Signal Acquisition: With a response time of 1 ms or less, the 140DDI35300 captures transient signals that slower modules might miss. This high-speed performance supports precise timing in high-throughput packaging or sorting applications.

  • High-Density I/O Footprint: Integrating 32 channels into a standard Quantum module format maximizes rack space. This density allows engineers to handle extensive field instrumentation without expanding the physical footprint of the PLC cabinet.

  • Comprehensive Visual Diagnostics: The front panel features 32 green LEDs for real-time input status, a red LED for external faults, and a green "Active" LED for bus communication. This immediate visual feedback simplifies onsite troubleshooting and reduces downtime during maintenance.

  • Industrial-Grade Isolation: The module provides 1780 Vrms isolation between the field groups and the backplane bus. This robust electrical barrier protects sensitive CPU electronics from field-side surges and ground loops, even in environments with heavy electromagnetic interference.

  • Global Certification Compliance: Holding certifications from ABS, BV, DNV, and GL, the 140DDI35300 meets the rigorous standards required for marine, offshore, and heavy industrial deployments worldwide.

FAQs

  • Does the 140DDI35300 support source or sink logic?

    The 140DDI35300 utilizes positive (sink) logic. Ensure your field wiring provides a positive voltage to the input terminals to trigger an "On" state.

  • What happens if the input voltage exceeds 30 V DC?

    The module features resistor-limited input protection and handles absolute maximums of 30 V continuous or 56 V during 1.3 ms pulses. However, exceeding 30 V for extended periods may cause thermal damage or trigger a fault state.

  • Is this a direct replacement for other Quantum DI modules?

    The 140DDI35300 fits standard Quantum backplanes. If you are replacing an older 16-point or different voltage module, you must update the hardware configuration in your Schneider Unity Pro or EcoStruxure Control Expert software to reflect the 32-point 24V DC mapping.

  • What is the guarantee of product condition?

    We guarantee this unit is 100% Brand New original Schneider Electric stock. It arrives in the original package with the factory seal and GTIN (3595861133815) intact.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more
Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Industrial automation relies on continuous operational stability to prevent catastrophic downtime and financial loss. While standard dictionary definitions treat redundancy as superfluous, industrial engineers consider redundant control architectures indispensable for high-availability systems. Implementing backup hardware ensures seamless takeover during primary equipment failures, protecting critical infrastructure across manufacturing and process industries.

Read more