Skip to content

What are you looking for?


You may also like

Yokogawa ACG10S-F2121 CENTUM VP Communication Gateway UnitYokogawa ACG10S-F2121 CENTUM VP Communication Gateway UnitYokogawa ACG10S-F2121 CENTUM VP Communication Gateway Unit
Yokogawa ACG10S-F2121 CENTUM VP Communication Gateway Unit
Yokogawa ACG10S-F2121 CENTUM VP Communication Gateway Unit
Yokogawa ACG10S-F2121 CENTUM VP Communication Gateway Unit

Yokogawa ACG10S-F2121 CENTUM VP Communication Gateway Unit


Only 10 left - Selling fast

PRODUCT SKU : ACG10S-F2121

PRODUCT TYPE : Communication Gateway Unit

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa ACG10S-F2121 functions as a high-performance Communication Gateway Unit designed for integrated production control systems. This unit bridges local control networks with wide-area Ethernet environments using specialized Frame Mode communication. It ensures uninterrupted data flow between Field Control Stations (FCS) and higher-level management systems. We provide this unit as 100% brand new and original equipment, ready for immediate integration into your automation architecture.

Part Number Breakdown

The model code ACG10S-F2121 S4 follows Yokogawa’s modular hardware identification system:

Code Segment Technical Definition
ACG10S Communication Gateway Unit
-F Frame Mode Communication
2 Dual-redundant V net (10BASE-5)
1 Wide area communication (Ethernet)
2 100-120 V AC Power supply
1 Desktop or 19-inch rack-mountable configuration
S4 Style 4 Hardware revision

Technical Specifications

The ACG10S-F2121 utilizes the following technical parameters to maintain network stability:

  • Communication Interface: Dual-redundant V net (10BASE-5)

  • External Network: Ethernet-based Wide Area Communication

  • Operating Mode: Frame Mode for optimized data packet handling

  • Voltage Requirement: 100-120 V AC

  • Mounting Compatibility: Standard 19" Rack or Desktop deployment

  • Hardware Weight: 0.6 kg

  • System Integrity: Supports seamless failover redundancy

  • Condition: Factory New, Original Packaging

Engineering Advantages

  • Eliminate Communication Bottlenecks: The Frame Mode architecture optimizes data throughput across the gateway. This prevents latency spikes when transmitting large volumes of process data from the plant floor to corporate Ethernet networks.

  • Bulletproof Redundancy: The unit employs dual-redundant V net interfaces. If one cable or port fails, the secondary path instantly takes over without data loss, ensuring the Human Interface Station (HIS) maintains constant visibility of the process.

  • Versatile Physical Deployment: Unlike bulkier gateway units, the ACG10S-F2121 supports both desktop placement for engineering stations and standard 19-inch rack mounting for central control rooms. This flexibility simplifies layout planning in space-constrained cabinets.

  • Low Thermal Impact: Weighing only 0.6 kg and utilizing efficient internal circuitry, this gateway generates minimal heat. This reduces the cooling load on your control cabinet, extending the lifespan of adjacent sensitive electronic components.

FAQs

  • Does this unit support 220V AC power?

    No. The ACG10S-F2121 is specifically configured for 100-120 V AC power. Attempting to power the unit with 220V will cause permanent hardware damage. Always verify your local power rails before installation.

  • How does the redundancy switchover work?

    The dual V net ports monitor signal integrity in real-time. The hardware handles the switchover at the physical layer, meaning your DCS software experiences no interruption during a path failure.

  • Can I mount this unit in a standard server rack?

    Yes. The unit accommodates standard 19-inch rack-mounting hardware. Ensure you maintain adequate clearance for the V net (10BASE-5) transceiver cables, as they require specific bend radii.

  • What is the significance of the "Frame Mode" setting?

    Frame Mode allows the gateway to pass raw data frames across the Ethernet bridge without complex protocol overhead, making it ideal for high-speed synchronization between distinct Yokogawa system domains

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more
Mastering PLC Power Supply Architectures and Operating Voltages

Mastering PLC Power Supply Architectures and Operating Voltages

Selecting the correct operating voltage is a critical step in designing reliable industrial automation systems. Whether you are working with a compact PLC or a large-scale DCS, your power architecture dictates the system's longevity. In this guide, we explore the standard voltage ranges and power distribution strategies required to maintain stable factory automation operations.

Read more