Skip to content

What are you looking for?


You may also like

YOKOGAWA RB301 RIO Bus Interface Master CardYOKOGAWA RB301 RIO Bus Interface Master CardYOKOGAWA RB301 RIO Bus Interface Master Card
YOKOGAWA RB301 RIO Bus Interface Master Card
YOKOGAWA RB301 RIO Bus Interface Master Card
YOKOGAWA RB301 RIO Bus Interface Master Card

YOKOGAWA RB301 RIO Bus Interface Master Card


Only 10 left - Selling fast

PRODUCT SKU : RB301

PRODUCT TYPE : Bus Interface Cards

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-speed RIO bus master communication and node device polling in CENTUM control systems, the YOKOGAWA RB301 S2 (RB301 RIO Bus Interface Master Card) provides direct physical/electrical execution. The half-length PCI card interfaces up to 31 RIO bus field devices per segment over a 10 Mbps serial link using a DB-37 connector.

Hardware Specifications

Parameter Specification
Model RB301 S2
Brand YOKOGAWA
Origin Japan
Weight 0.3 kg
Dimensions Half-length PCI form factor
Operating Temp -20 to 60 deg C
Storage Temp -40 to 85 deg C
Humidity 5 to 95% RH (non-condensing)
Power Consumption 5 W
Bus Interface RIO bus
Bus Transmission Speed 10 Mbps
Physical Connector DB-37 female
Maximum Capacity Up to 31 devices per segment

4-20 mA HART Loop Protocol and RIO Bus Data Acquisition

The RB301 master card facilitates deterministic cyclic telemetry exchanges between the host processor backplane and distributed field I/O nodes. Transmitted signals encompass process variables collected from 4-20 mA HART loop protocol instruments and field sensors connected to remote I/O sub-assemblies. Operating over a 10 Mbps RIO bus layer, the interface manages hardware polling cycles and packet framing across DB-37 multi-conductor cables while maintaining signal integrity across industrial noise profiles.

Frequently Asked Questions

Q: How many field I/O devices can be connected to a single RB301 master card segment?

A: A single RB301 master card segment supports up to 31 Yokogawa RIO bus field devices connected in a daisy-chain or drop topology.

Q: What host expansion slot is required to install the RB301 card?

A: The card requires a standard half-length PCI expansion slot on the host computer or Human Interface Station (HIS) backplane.

Q: What is the transmission speed of the DB-37 RIO bus interface?

A: The RB301 operates at a fixed bus communication speed of 10 Mbps over the DB-37 connector interface.

Field Installation Guidelines

Power down the host workstation and disconnect the main AC supply before installing or removing the RB301 PCI card. Observe strict electrostatic discharge (ESD) procedures, wearing a grounded wrist strap when handling the printed circuit board. Insert the card securely into a vacant PCI slot on the motherboard and fasten the bracket mounting screw to ensure frame ground continuity. Connect the DB-37 cable assembly, locking the thumb screws firmly. Ensure shielded twisted-pair cables are grounded at a single earth ground point to prevent ground loop currents from interfering with 10 Mbps signal transmission.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more