Skip to content

What are you looking for?


You may also like

YOKOGAWA ADM51 CENTUM Contact Output ModuleYOKOGAWA ADM51 CENTUM Contact Output ModuleYOKOGAWA ADM51 CENTUM Contact Output Module
YOKOGAWA ADM51 CENTUM Contact Output Module
YOKOGAWA ADM51 CENTUM Contact Output Module
YOKOGAWA ADM51 CENTUM Contact Output Module

YOKOGAWA ADM51 CENTUM Contact Output Module


Only 10 left - Selling fast

PRODUCT SKU : ADM51

PRODUCT TYPE : Digital Output Modules

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The YOKOGAWA ADM51, also cataloged as the ADM51 Contact Output Card, operates as a dedicated hardware component for discrete signal switching and relay execution within Yokogawa CENTUM CS 3000 distributed control system architectures.

Hardware Specifications

Parameter Specification
Model ADM51
Brand YOKOGAWA
Origin Japan
Weight 0.1 kg
Dimensions 22.9 cm x 2.5 cm x 7.6 cm
Output Channels 16-point contact output
Contact Types Mechanical relay or solid-state
System Compatibility Yokogawa CENTUM CS 3000 DCS

Channel-to-Channel Isolation and DCS Integration

The ADM51 contact output card interfaces discrete field actuators, solenoids, and alarm indicators with the CENTUM CS 3000 system backplane. Galvanic and channel-to-channel isolation barriers protect system control electronics from inductive kickback, field voltage surges, and common-mode interference. The discrete switching logic operates in parallel with 4-20 mA HART loop protocol analog sub-assemblies, providing deterministic state execution without inducing cross-talk on adjacent DCS I/O cards.

Frequently Asked Questions

Q: What output contact switching options are supported on the ADM51 card?

A: The card utilizes either mechanical relay or solid-state contacts across its 16 output channels to suit varied field voltage and load switching requirements.

Q: How does the ADM51 output card interface with field devices in a CENTUM rack?

A: The card mounts directly into the node rack and routes its 16 discrete contact outputs through dedicated backplane cabling to external field terminal blocks.

Field Installation Guidelines

De-energize field power supplies and the host node rack backplane prior to card installation or removal. Observe electrostatic discharge (ESD) protection procedures by wearing a grounded wrist strap when handling the card. Insert the ADM51 vertically along the rack guide rails until the backplane connector seats completely into the slot socket. Tighten top and bottom retaining screws to establish structural retention and frame grounding continuity. Route discrete output wiring separately from high-voltage AC lines and analog signal cables to prevent electromagnetic coupling. Ensure external inductive loads are wired with suppression circuits to prevent contact arcing during output state transitions.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more