Skip to content

What are you looking for?


You may also like

Yokogawa AAI143-S50 16-Channel Isolated Analog Input ModuleYokogawa AAI143-S50 16-Channel Isolated Analog Input ModuleYokogawa AAI143-S50 16-Channel Isolated Analog Input Module
Yokogawa AAI143-S50 16-Channel Isolated Analog Input Module
Yokogawa AAI143-S50 16-Channel Isolated Analog Input Module
Yokogawa AAI143-S50 16-Channel Isolated Analog Input Module

Yokogawa AAI143-S50 16-Channel Isolated Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : AAI143-S50

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The AAI143-S50 analog input module from Yokogawa is designed for precise measurement of industrial signals in distributed control systems. With 16 isolated input channels, this unit supports 4–20 mA DC signals and integrates HART communication for advanced diagnostics and configuration. Its robust electrical isolation and redundancy compatibility make it suitable for mission-critical applications.

Technical Specifications

  • Manufacturer: Yokogawa

  • Model Number: AAI143-S50

  • Type: Isolated Analog Input Module

  • Channels: 16 isolated input channels

  • Signal Range: 4–20 mA DC

  • Allowable Input Current: Up to 24 mA

  • Withstanding Voltage: 1500 V AC between input and system (1 minute)

  • Input Resistance:

    • Power ON: 270 Ω at 20 mA, 350 Ω at 4 mA

    • Power OFF: ≥500 kΩ

  • Accuracy: ±16 µA

  • Data Update Period: 10 ms

  • Transmitter Power Supply:

    • ≥19.0 V at 20 mA

    • ≤25.5 V at 0 mA (with current limit of 25 mA)

  • Transmitter Configuration: Supports 2-wire and 4-wire transmitters via setting pin

  • Temperature Drift: ±16 µA per 10 °C change

  • Current Consumption: 230 mA (5 V DC), 540 mA (24 V DC)

  • Weight: 0.3 kg

  • External Connections: Pressure clamp terminal, MIL connector cable, KS1 dedicated cable

  • Communication Protocol: HART-enabled

Key Features

  • Isolated Channels: Ensures reliable signal integrity

  • HART Communication: Enables remote diagnostics and configuration

  • Redundancy Support: Compatible with dual-redundant setups

  • High Accuracy: Stable measurement across varying conditions

  • Compact Design: Lightweight and efficient for cabinet installation

Application Scenarios

  • Chemical and petrochemical process monitoring

  • Power generation instrumentation

  • Water treatment and distribution automation

  • Industrial automation requiring isolated multi-channel input

FAQ

Q: How many channels does the AAI143-S50 provide?  A: It supports 16 isolated analog input channels.

Q: Does this module support redundancy?  A: Yes, it is compatible with dual-redundant configurations.

Q: What communication protocol is available?  A: The module supports HART communication.

Comparison with Similar Models

  • AAI143-S00: Standard analog input module without extended options

  • AAI143-H53: HART-enabled version with ISA G3 compliance

  • AAI143-S50: Advanced model with HART support and redundancy capability

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Implementing FIFO and LIFO Data Sequencing in PLC Programming

Implementing FIFO and LIFO Data Sequencing in PLC Programming

Data management serves as a cornerstone of modern industrial automation. Whether tracking materials on a conveyor or managing batch sequences in a process, engineers frequently rely on sequential logic. Two primary structures—First-In-First-Out (FIFO) and Last-In-First-Out (LIFO)—form the bedrock of this data handling. Mastering these blocks allows programmers to optimize complex machine operations efficiently.

Read more
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more