Product Description

The AAI143-H50 analog input module from Yokogawa is designed for distributed control systems requiring accurate current signal acquisition. This model provides 16 isolated input channels for 4–20 mA DC signals, ensuring reliable measurement and integration with smart field devices. The H50 suffix indicates HART communication support, no explosion protection, and basic hardware type.

Technical Specifications

  • Manufacturer: Yokogawa

  • Model Number: AAI143-H50

  • Type: Isolated Analog Input Module

  • Channels: 16 isolated input channels

  • Signal Range: 4–20 mA DC

  • Allowable Input Current: 24 mA

  • Withstanding Voltage: 1500 V AC between input and system (1 minute)

  • Input Resistance:

    • Power ON: 270 Ω at 20 mA, 350 Ω at 4 mA

    • Power OFF: ≥500 kΩ

  • Accuracy: ±16 µA

  • Data Update Period: 10 ms

  • Transmitter Power Supply: 19.0 V minimum at 20 mA, 25.5 V maximum at 0 mA (limit 25 mA)

  • Transmitter Configuration: Supports 2-wire and 4-wire transmitters via setting pin

  • Temperature Drift: ±16 µA per 10 °C change

  • Current Consumption: 230 mA (5 V DC), 540 mA (24 V DC)

  • Weight: 0.3 kg (Shipping weight: 2.0 kg)

  • External Connections: Pressure clamp terminal, MIL connector cable, KS1 cable

  • Communication Protocol: HART-enabled

Suffix Code Breakdown

  • H: HART communication support

  • 5: No explosion protection

  • 0: Basic hardware type

Key Features

  • Isolated Channels: Ensures reliable signal integrity

  • HART Communication: Enables diagnostics and remote configuration

  • High Accuracy: ±16 µA precision for stable measurement

  • Compact Design: Lightweight and efficient for cabinet installation

Application Scenarios

  • Chemical and petrochemical process monitoring

  • Power generation instrumentation

  • Water treatment and distribution systems

  • Industrial automation requiring isolated multi-channel input

FAQ

Q: How many channels does the AAI143-H50 provide?  A: It supports 16 isolated analog input channels.

Q: What does the suffix “H50” indicate?  A: It specifies HART communication support, no explosion protection, and basic hardware type.

Q: Is redundancy supported?  A: Yes, the module is compatible with dual-redundant configurations.

Comparison with Similar Models

  • AAI143-S00: Standard analog input module without HART support

  • AAI143-H53: HART-enabled version with ISA G3 compliance

  • AAI143-H50: HART-enabled with basic hardware type

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Implementing FIFO and LIFO Data Sequencing in PLC Programming

Implementing FIFO and LIFO Data Sequencing in PLC Programming

Data management serves as a cornerstone of modern industrial automation. Whether tracking materials on a conveyor or managing batch sequences in a process, engineers frequently rely on sequential logic. Two primary structures—First-In-First-Out (FIFO) and Last-In-First-Out (LIFO)—form the bedrock of this data handling. Mastering these blocks allows programmers to optimize complex machine operations efficiently.

Read more
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more