Skip to content

What are you looking for?


You may also like

AAI543-H50 / A4S00 | Yokogawa | Isolated Analog Output Module | 16-ChannelAAI543-H50 / A4S00 | Yokogawa | Isolated Analog Output Module | 16-ChannelAAI543-H50 / A4S00 | Yokogawa | Isolated Analog Output Module | 16-Channel
AAI543-H50 / A4S00 | Yokogawa | Isolated Analog Output Module | 16-Channel
AAI543-H50 / A4S00 | Yokogawa | Isolated Analog Output Module | 16-Channel
AAI543-H50 / A4S00 | Yokogawa | Isolated Analog Output Module | 16-Channel

AAI543-H50 / A4S00 | Yokogawa | Isolated Analog Output Module | 16-Channel


Only 10 left - Selling fast

PRODUCT SKU : AAI543-H50/A4S00

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The AAI543-H50 / A4S00 analog output module from Yokogawa is engineered for distributed control systems requiring precise and reliable signal transmission. With 16 isolated output channels, it delivers 4–20 mA analog signals with high accuracy and stability. The H50 suffix indicates HART protocol support and redundancy capability, while the A4S00 option adds a pressure clamp terminal block (Model: ATA4S-00) for secure and flexible wiring.

Technical Specifications

  • Manufacturer: Yokogawa

  • Model Number: AAI543-H50 / A4S00

  • Type: Isolated Analog Output Module

  • Channels: 16 isolated output channels

  • Output Signal Range: 4–20 mA DC

  • Digital Communication: HART protocol supported

  • Redundancy: Standard switch-over response supported

  • Withstanding Voltage: 1500 V AC (output to system, 1 minute)

  • Allowable Load Resistance: 0–750 Ω

  • Circuit-Open Detection Threshold: <0.65 mA

  • Accuracy: ±0.05% of full scale

  • Response Time: 1 ms

  • Temperature Drift: ±16 µA per 10 °C

  • Operating Temperature Range: -40°C to +85°C

  • Power Consumption: 230 mA @ 5 V DC, 540 mA @ 24 V DC

  • External Connection: Pressure clamp terminal block (ATA4S-00)

  • Dimensions (W × H × D): 170 × 120 × 45 mm

  • Weight: 0.4 kg

Suffix Code Breakdown

  • H: HART communication support

  • 5: Standard switch-over redundancy, no explosion protection

  • 0: Basic hardware type

  • /A4S00: Adds ATA4S-00 pressure clamp terminal block

Key Features

  • High Accuracy: ±0.05% FS ensures precise control signals

  • Fast Response: 1 ms output response for dynamic applications

  • HART Integration: Enables diagnostics and remote configuration

  • Redundancy Support: Fail-safe operation in critical systems

  • Environmental Durability: Wide operating range (-40°C to +85°C)

Application Scenarios

  • Valve and actuator control in chemical plants

  • Power generation and turbine monitoring

  • Water treatment and distribution automation

  • Industrial machinery requiring precise analog actuation

FAQ

Q: How many channels does the AAI543-H50 / A4S00 provide?  A: It supports 16 isolated analog output channels.

Q: What does the suffix “A4S00” indicate?  A: It specifies the inclusion of a pressure clamp terminal block (ATA4S-00).

Q: Is redundancy supported?  A: Yes, the module includes standard switch-over response in redundant setups.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Implementing FIFO and LIFO Data Sequencing in PLC Programming

Implementing FIFO and LIFO Data Sequencing in PLC Programming

Data management serves as a cornerstone of modern industrial automation. Whether tracking materials on a conveyor or managing batch sequences in a process, engineers frequently rely on sequential logic. Two primary structures—First-In-First-Out (FIFO) and Last-In-First-Out (LIFO)—form the bedrock of this data handling. Mastering these blocks allows programmers to optimize complex machine operations efficiently.

Read more
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more