Skip to content

What are you looking for?


You may also like

AAI135-H53/K4A00 | Yokogawa CENTUM VP 8-Channel HART Isolated Analog Input ModuleAAI135-H53/K4A00 | Yokogawa CENTUM VP 8-Channel HART Isolated Analog Input ModuleAAI135-H53/K4A00 | Yokogawa CENTUM VP 8-Channel HART Isolated Analog Input Module
AAI135-H53/K4A00 | Yokogawa CENTUM VP 8-Channel HART Isolated Analog Input Module
AAI135-H53/K4A00 | Yokogawa CENTUM VP 8-Channel HART Isolated Analog Input Module
AAI135-H53/K4A00 | Yokogawa CENTUM VP 8-Channel HART Isolated Analog Input Module

AAI135-H53/K4A00 | Yokogawa CENTUM VP 8-Channel HART Isolated Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : AAI835-H53/K4A00

PRODUCT TYPE : Analog I/O Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The AAI135-H53/K4A00 (Part Number AAI135-H53/K4A00) is a ruggedized, high-density analog input module purpose-built for the Yokogawa CENTUM VP distributed control system. This specific variant is engineered for resilience, featuring the ISA Standard G3 conformal coating to withstand corrosive gaseous environments and an extended operating temperature range for deployment in volatile climates. It facilitates the precise acquisition of 4 to 20 mA signals from up to eight isolated field transmitters, ensuring electrical faults on one channel do not propagate through the system.

A key technical advantage of the AAI135-H53/K4A00 is its integrated HART digital communication capability. This allows the DCS to transparently access instrument diagnostics and secondary variables from smart field devices. For streamlined installation, this module is equipped with the ATK4A-00 KS Cable Interface Adapter, allowing for rapid, high-reliability connection via multi-core cables rather than individual screw terminals.

Technical Specifications

  • Input Channels 8 channels, fully isolated from the system and between channels

  • Input Signal Range 4 to 20 mA DC

  • Digital Communication HART protocol (Pass-through functionality)

  • Environmental Protection ISA Standard G3 conformal coating (Corrosion resistant)

  • Operating Temperature -20°C to 70°C (-4°F to 158°F)

  • Input Impedance 250 Ω (During power-on)

  • Accuracy ±16 μA (at 23°C ± 2°C)

  • Data Update Cycle 40 ms internal refresh rate

  • Withstand Voltage 1500 V AC for 1 minute (Input-to-System)

  • External Connection KS Cable Interface via ATK4A-00 adapter

  • Current Consumption 5 V DC at 320 mA and 24 V DC at 450 mA

  • Module Weight 0.3 kg (shipping weight approximately 2.0 kg with packaging)

Suffix and Configuration Codes

  • AAI135 Base series for 8-channel isolated current input

  • -H Integrated HART communication support

  • 5 Standard version without explosion-proof rating

  • 3 Enhanced environmental package (G3 coating and wide temperature support)

  • K4A00 Includes the ATK4A-00 adapter for KS cable connectivity

Application Scenarios

  • Harsh chemical processing plants where sulfur dioxide or hydrogen sulfide levels require G3 protection.

  • Remote instrument enclosures subject to wide seasonal temperature variations.

  • Critical process loops requiring channel-to-channel isolation to eliminate ground loops.

  • Asset management systems utilizing HART data for predictive maintenance of transmitters.

Frequently Asked Questions

What is the benefit of the G3 option on this module?

The "3" suffix indicates the AAI135-H53/K4A00 meets ISA-S71.04 severity level G3. This means the internal components are coated to resist corrosion from harsh industrial gases, extending the hardware lifespan in refineries and paper mills.

Does this module require a separate terminal block?

Because this version includes the /K4A00 adapter, it is designed to connect directly to a Yokogawa KS cable. This is typically used when connecting to a terminal board or a Marshalling panel, providing a cleaner and faster installation compared to individual pressure clamp terminals.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Implementing FIFO and LIFO Data Sequencing in PLC Programming

Implementing FIFO and LIFO Data Sequencing in PLC Programming

Data management serves as a cornerstone of modern industrial automation. Whether tracking materials on a conveyor or managing batch sequences in a process, engineers frequently rely on sequential logic. Two primary structures—First-In-First-Out (FIFO) and Last-In-First-Out (LIFO)—form the bedrock of this data handling. Mastering these blocks allows programmers to optimize complex machine operations efficiently.

Read more
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more