Skip to content

What are you looking for?


You may also like

AAI135-H00 / K4A00 | Yokogawa | 8-Channel Analog Input ModuleAAI135-H00 / K4A00 | Yokogawa | 8-Channel Analog Input ModuleAAI135-H00 / K4A00 | Yokogawa | 8-Channel Analog Input Module
AAI135-H00 / K4A00 | Yokogawa | 8-Channel Analog Input Module
AAI135-H00 / K4A00 | Yokogawa | 8-Channel Analog Input Module
AAI135-H00 / K4A00 | Yokogawa | 8-Channel Analog Input Module

AAI135-H00 / K4A00 | Yokogawa | 8-Channel Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : AAI135-H00/K4A00

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The AAI135-H00 / K4A00 analog input module from Yokogawa is designed for distributed control systems requiring isolated current input channels with high accuracy and robust electrical isolation. This model provides 8 isolated input channels operating in the 4–20 mA DC range, making it suitable for precise monitoring of transmitters and sensors in demanding industrial environments. The H00 suffix indicates HART protocol support, while the K4A00 option provides compatibility with the KS cable interface adapter (Model: ATK4A-00).

Technical Specifications

  • Manufacturer: Yokogawa

  • Model Number: AAI135-H00 / K4A00

  • Type: Analog Input Module (Current Input)

  • Channels: 8 isolated input channels

  • Signal Range: 4–20 mA DC

  • Allowable Input Current: 25 mA

  • Withstanding Voltage:

    • Between input and system: 500 V AC for 1 minute

    • Between input channels: 500 V AC for 1 minute

  • Input Resistance:

    • Power ON: 290 Ω at 20 mA, 450 Ω at 4 mA

    • Power OFF: ≥500 kΩ

  • Accuracy: ±16 µA

  • Dimensions (W × H × D): 3.4 × 10.8 × 13 cm

  • Weight: 0.3 kg

  • Shipping Weight: 2.0 kg

  • Suffix Codes:

    • H: HART protocol support

    • 00: Basic type

    • K4A00: KS cable interface adapter option

Key Features

  • Isolated Channels: Enhanced reliability and reduced interference

  • HART Communication: Enables digital diagnostics and remote configuration

  • Compact Design: Lightweight and efficient for cabinet installation

  • High Accuracy: Stable measurement across industrial environments

  • Flexible Connectivity: KS cable adapter option for extended interface compatibility

Application Scenarios

  • Chemical and petrochemical process monitoring

  • Power generation instrumentation

  • Water treatment and distribution systems

  • General industrial automation requiring isolated analog inputs

FAQ

Q: How many channels does the AAI135-H00 provide?  A: It supports 8 isolated analog input channels.

Q: What does the K4A00 suffix indicate?  A: It specifies compatibility with the KS cable interface adapter (ATK4A-00).

Q: Is HART communication supported?  A: Yes, the H00 suffix indicates HART protocol support.

Comparison with Similar Models

  • AAI135-S00: Standard analog input module without HART support

  • AAI135-H00: HART-enabled version with isolated channels

  • AAI135-H00/K4A00: Advanced model with HART support and KS cable adapter option

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Implementing FIFO and LIFO Data Sequencing in PLC Programming

Implementing FIFO and LIFO Data Sequencing in PLC Programming

Data management serves as a cornerstone of modern industrial automation. Whether tracking materials on a conveyor or managing batch sequences in a process, engineers frequently rely on sequential logic. Two primary structures—First-In-First-Out (FIFO) and Last-In-First-Out (LIFO)—form the bedrock of this data handling. Mastering these blocks allows programmers to optimize complex machine operations efficiently.

Read more
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more