PRODUCT SKU : 8112

PRODUCT TYPE : Remote Expansion Chassis

PRODUCT VENDOR : Triconex


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Triconex 8112, also cataloged as the 8112 Remote Expansion Chassis, operates as a dedicated hardware component for high-density I/O module housing and system bus distribution within Tricon safety system platforms.

Hardware Specifications

Parameter Specification
Model 8112
Brand Triconex
Origin USA
Weight 24.5 kg
Dimensions 48.3 cm x 57.8 cm x 45.1 cm
Operating Temp Not specified (Refer to system thermal derating)
Power Consumption Dependent on installed I/O module load
Chassis Fabrication Black zinc-plated, welded cold-rolled steel
Capacity High-density modular slots

Triple Modular Redundancy (TMR) Architectural Integration

The Triconex 8112 is engineered to support the physical implementation of the TMR 2oo3 architecture. The chassis backplane facilitates the necessary inter-module communication paths required to maintain triple-redundant signal processing. By providing standardized mechanical slots and bus connectivity, the chassis ensures that each redundant leg of the TMR system remains electrically isolated and mechanically secure. The fabrication of cold-rolled steel provides the structural rigidity required for high-density deployments, while the integrated backplane design supports the high-speed data exchange necessary for real-time fault detection and continuous fail-safe state execution across the safety system.

Frequently Asked Questions

Q: Can the 8112 chassis accommodate different types of I/O modules simultaneously?

A: Yes, the chassis backplane is designed to support mixed-module configurations, including analog and digital I/O, provided they adhere to the Tricon power and slot-assignment requirements.

Q: Is the 8112 chassis capable of hot-swapping modules during operation?

A: Yes, the system architecture allows for the removal and insertion of modules within the 8112 chassis while the system is powered and operational, provided the specific module type is designated for hot-swap capability.

Field Installation Guidelines

  1. Ensure the chassis is mounted into a standard 19-inch rack with adequate clearance for airflow to maintain proper thermal dissipation.
  2. Verify that the chassis frame is bonded to a dedicated ground bus to maintain EMC integrity and protection against common-mode noise.
  3. Install the power supply modules prior to loading the I/O modules to ensure the backplane is energized correctly.
  4. When securing the chassis to the rack, ensure all mounting bolts are tightened to specified torque values to prevent vibration-induced mechanical stress.
  5. Inspect all backplane connectors for debris or contact oxidation prior to seating any modules to ensure low-resistance system bus communication.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more
Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Industrial automation has evolved from a simple manufacturing tool into the operational backbone of high-risk sectors. Modern mining operations increasingly rely on advanced control systems, programmable logic controllers (PLCs), distributed control systems (DCS), and artificial intelligence to address deep-underground hazards. By replacing manual labor in high-risk zones, factory automation technologies protect personnel while significantly boosting operational throughput.

Read more