Skip to content

What are you looking for?


You may also like

Bently Nevada 3500/91-01-02-00 Communication Gateway Module for Industrial MonitoringBently Nevada 3500/91-01-02-00 Communication Gateway Module for Industrial MonitoringBently Nevada 3500/91-01-02-00 Communication Gateway Module for Industrial Monitoring
Bently Nevada 3500/91-01-02-00 Communication Gateway Module for Industrial Monitoring
Bently Nevada 3500/91-01-02-00 Communication Gateway Module for Industrial Monitoring
Bently Nevada 3500/91-01-02-00 Communication Gateway Module for Industrial Monitoring

Bently Nevada 3500/91-01-02-00 Communication Gateway Module for Industrial Monitoring


Only 10 left - Selling fast

PRODUCT SKU : 3500/91-01-02-00

PRODUCT TYPE : Gateway Module

PRODUCT VENDOR : Bently Nevada


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Description

The Bently Nevada 3500/91-01-02-00 Communication Gateway Module is designed to enable seamless data exchange between the 3500 Series monitoring system and external control networks. It supports both Ethernet and serial communication protocols.

Specifications

  • Model: 3500/91-01-02-00

  • Manufacturer: Bently Nevada, a Baker Hughes company

  • Country of Origin: United States

  • Supported Protocols: Ethernet TCP/IP, RS232, RS422, RS485

  • Function: Transmits monitored values and system status from the rack

  • Response Time: Suitable for real-time controller applications

  • Dimensions: 241.3 mm × 24.4 mm × 241.8 mm

  • Weight: Approximately 0.79 kg

  • Installation: Fits into standard 3500 Series rack systems

  • Power Supply: Provided via rack backplane

Features

  • EGD Support: Enables Ethernet Global Data communication for high-speed data sharing

  • Dual Interface: Offers both Ethernet and serial connectivity options

  • System Integration: Connects 3500 Series with SCADA and enterprise control systems

  • Real-Time Monitoring: Facilitates fast and reliable condition data transmission

  • Scalable Architecture: Easily expandable within existing 3500 Series setups

  • Industrial Reliability: Engineered for continuous operation in demanding environments

  • Comprehensive Data Access: Provides access to vibration, temperature, pressure, and speed data

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying PLC Memory: A Technical Guide to Architecture, Retention, and Performance

Demystifying PLC Memory: A Technical Guide to Architecture, Retention, and Performance

Modern industrial automation relies heavily on the reliability of programmable logic controllers (PLCs). At the heart of every PLC lies its memory system. This subsystem directly dictates scan times, program capacity, and data survival during power outages. For field engineers, understanding how a control system allocates, retains, and secures this memory is essential for writing efficient code and preventing costly downtime.

Read more
Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

The transition of a Programmable Logic Controller (PLC) cabinet from a controlled factory floor to a volatile plant environment represents a critical milestone in factory automation. While a Factory Acceptance Test (FAT) validates standalone hardware compliance under ideal conditions, it cannot replicate real-world process dynamics. Therefore, deploying an industrial automation system requires a rigorous Site Acceptance Test (SAT) to verify total loop integrity, field wiring wiring metrics, and process control parameters before final customer handover.

Read more
Advanced Integration: Master Protocol for VFD Commissioning and Testing

Advanced Integration: Master Protocol for VFD Commissioning and Testing

Deploying variable frequency drives (VFDs) requires precise execution during the initial commissioning phase. Junior automation engineers often find the first power-up sequence intimidating. However, following a rigorous engineering framework ensures equipment safety and system reliability. Proper startup procedures protect both the drive electronics and the connected motor.

Read more