Skip to content

What are you looking for?


You may also like

Schneider 170AAI52040 Modicon Momentum 4-Channel Distributed Analog Input ModuleSchneider 170AAI52040 Modicon Momentum 4-Channel Distributed Analog Input ModuleSchneider 170AAI52040 Modicon Momentum 4-Channel Distributed Analog Input Module
Schneider 170AAI52040 Modicon Momentum 4-Channel Distributed Analog Input Module
Schneider 170AAI52040 Modicon Momentum 4-Channel Distributed Analog Input Module
Schneider 170AAI52040 Modicon Momentum 4-Channel Distributed Analog Input Module

Schneider 170AAI52040 Modicon Momentum 4-Channel Distributed Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : 170AAI52040

PRODUCT TYPE : Distributed Analog Input Module

PRODUCT VENDOR : Schneider


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Schneider 170AAI52040 Distributed Analog Input Module is engineered for high-precision industrial automation applications. Designed for the Modicon Momentum platform, this module provides four differential analog input channels with 15-bit resolution and supports a wide range of sensor types, including thermocouples and RTDs. Its robust isolation and high common-mode rejection ensure accurate signal acquisition in electrically noisy environments.

Technical Specifications

  • Manufacturer Schneider Electric

  • Model 170AAI52040

  • Product Type Distributed Analog Input Module

  • Number of Inputs 4 analog channels

  • Input Type Differential

  • Analog Input Range ±25 mV, ±100 mV

  • Thermocouple Types E, S, K, N, B, R, J, T

  • Temperature Probe Types Ni100, Ni1000, Pt100, Pt1000

  • Data Format 16-bit signed

  • Absolute Accuracy Error

    • ±21 μV at 25°C for ±25 mV

    • ±25 μV at 25°C for ±100 mV

    • ±46 μV at 60°C for ±25 mV

    • ±94 μV at 60°C for ±100 mV

  • Update Time 500 ms

  • Isolation

    • 400 V DC between channels

    • 500 V AC for 1 minute between channels and ground

    • 500 V AC for 1 minute between supply and ground

  • Permissible Common Mode Voltage

    • 100 V DC between channels and ground

    • 15 V AC single or three-phase between channels

    • 200 V DC between channels

    • 250 V AC between channels and ground

    • 250 V AC single-phase between channels

  • Common Mode Rejection

    • 120 dB DC between channels

    • 130 dB 50 Hz AC between channels

    • 135 dB DC channels to ground

    • 140 dB 60 Hz AC channels

    • 145 dB 50 Hz AC channels to ground

    • 155 dB 60 Hz AC channels to ground

Application Scenarios

  • Acquisition of precise analog signals in industrial control systems

  • Temperature monitoring using thermocouples or RTDs

  • Integration with Modicon Momentum PLC systems for distributed analog measurement

  • Replacement or expansion of existing analog input modules in Momentum installations

FAQs

  • Q1: How many analog inputs does the 170AAI52040 support?
    A1: It supports four differential analog input channels.

  • Q2: What types of sensors are compatible?
    A2: Thermocouples (E, S, K, N, B, R, J, T) and RTDs (Ni100, Ni1000, Pt100, Pt1000).

  • Q3: What isolation levels are provided?
    A3: 400 V DC between channels, 500 V AC between channels and ground, and 500 V AC between supply and ground.

  • Q4: What is the update time for measurements?
    A4: 500 milliseconds per scan cycle.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more