Skip to content

What are you looking for?


You may also like

Schneider BMXXBP1002 Modicon X80 Ethernet Backplane RackSchneider BMXXBP1002 Modicon X80 Ethernet Backplane RackSchneider BMXXBP1002 Modicon X80 Ethernet Backplane Rack
Schneider BMXXBP1002 Modicon X80 Ethernet Backplane Rack
Schneider BMXXBP1002 Modicon X80 Ethernet Backplane Rack
Schneider BMXXBP1002 Modicon X80 Ethernet Backplane Rack

Schneider BMXXBP1002 Modicon X80 Ethernet Backplane Rack


Only 10 left - Selling fast

PRODUCT SKU : BMXXBP1002

PRODUCT TYPE : Backplane Racks

PRODUCT VENDOR : Schneider


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Schneider BMXXBP1002, also cataloged as the BMXXBP1002 Ethernet Backplane Rack, operates as a dedicated hardware component for physical module housing and backplane data routing within Modicon M580 and M340 PAC platforms. It provides structural mounting and dual Ethernet/X-bus communication paths across 10 system slots.

Hardware Specifications

Parameter Specification
Model BMXXBP1002
Brand Schneider Electric
Origin France
Weight 1.37 kg
Dimensions 59.0 cm x 15.3 cm x 6.6 cm (Package 1 dimension)
Operating Temp 0 to 60 deg C
Power Consumption 251 mW at 3.3 VDC, 3.9 W at 24 VDC
Number of Slots 10 Slots (8 Bus X + Ethernet, 2 Bus X)
Current Consumption 162 mA at 24 VDC, 76 mA at 3.3 VDC
Protection Rating IP20
Relative Humidity 5 to 95 % without condensation
Fixing Mode 4 M6 screws on plate or 4 screws (4.32-6.35 mm diameter) on panel
System Compatibility BMXCPS4002 Power Supply, BMX Processor, BME Processor, X80 I/O Modules
Auxiliary Connection 1 connector (XBE) expansion module interface

Ethernet/X-Bus Backplane Deterministic Communication

The BMXXBP1002 incorporates a dual-bus architecture integrating a high-speed Ethernet backplane alongside the legacy X-bus channel. The dual-bus design enables high-bandwidth, deterministic EtherNet/IP communication directly across the 8 dedicated Ethernet slots for complex process modules and BME processors, while maintaining backward compatibility for standard X-bus I/O cards. Internal signal routing ensures synchronized backplane bus communication velocity across all slots, shielding high-density I/O transactions from data collision and bus arbitration latencies.

Frequently Asked Questions

Q: What is the structural difference between the 10 available slots on the BMXXBP1002?

A: The rack features 8 hybrid slots that support combined Bus X and Ethernet backplane connectivity for advanced processors and network modules, alongside 2 dedicated Bus X slots reserved exclusively for standard X-bus I/O modules.

Q: Can multiple BMXXBP1002 backplane racks be daisy-chained together?

A: Yes. The rack is equipped with an XBE expansion module connector slot, allowing local rack expansion via dedicated X-bus extension cables to connect secondary racks.

Q: What power supplies are compatible with the BMXXBP1002 backplane slot footprint?

A: The backplane directly interfaces with Modicon X80 power supply units, such as the BMXCPS4002, which distribute required 3.3 VDC and 24 VDC operating voltages across the internal backplane traces.

Field Installation Guidelines

  1. Mount the backplane rack firmly onto a grounded enclosure backplate using four M6 screws or panel mounting hardware with a screw diameter between 4.32 mm and 6.35 mm.
  2. Ensure the grounding strip on the back panel makes clean metal-to-metal contact with the enclosure chassis to satisfy EN 61000-6-2 electromagnetic compatibility requirements.
  3. Seat the BMXCPS4002 or compatible Modicon X80 power supply in the left-most dedicated power slot before powering up the backplane.
  4. If utilizing multi-rack configurations, connect the XBE expansion cable to the side port and verify termination block placement on the last physical rack in the chain.
  5. Maintain IP20 ingress compliance by housing the rack assembly inside a NEMA/IP-rated protective enclosure free from conductive dust and corrosive fumes.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying the 5 Levels of Industrial Automation Architecture

Demystifying the 5 Levels of Industrial Automation Architecture

Modern manufacturing relies on structured communication hierarchy to bridge physical shop-floor hardware with enterprise management software. This framework, commonly known as the Automation Pyramid, establishes how data flows between field devices, logic controllers, and corporate IT networks. Understanding these five distinct levels helps engineers and plant managers optimize system operations, reduce downtime, and implement seamless factory automation solutions.

Read more
Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Manufacturing Execution Systems serve as the digital backbone of modern factory floors. Positioned at Level 3 of the ISA-95 automation pyramid, MES links enterprise resource planning with real-time shop floor control systems. Today, industrial operators rely on MES software to bridge operational strategy with physical production execution.

Read more
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more