Skip to content

What are you looking for?


You may also like

HIMA F 6217/F6217 | 8-Channel Analog Input Module | HIMatrix Safety SystemHIMA F 6217/F6217 | 8-Channel Analog Input Module | HIMatrix Safety SystemHIMA F 6217/F6217 | 8-Channel Analog Input Module | HIMatrix Safety System
HIMA F 6217/F6217 | 8-Channel Analog Input Module | HIMatrix Safety System
HIMA F 6217/F6217 | 8-Channel Analog Input Module | HIMatrix Safety System
HIMA F 6217/F6217 | 8-Channel Analog Input Module | HIMatrix Safety System

HIMA F 6217/F6217 | 8-Channel Analog Input Module | HIMatrix Safety System


Only 10 left - Selling fast

PRODUCT SKU : F6217

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Hima


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Technical Overview

The HIMA F 6217 is a high-precision, safety-related analog input module engineered for the HIMatrix F and M series controllers. This 8-fold module is designed to interface with critical sensors in environments requiring up to SIL 3 certification. It features integrated safety isolation and supports both current and voltage signals, providing the rapid response times essential for emergency shutdown (ESD) and high-pressure protection (HIPPS) applications.

Detailed Specifications

  • Module Type: 8-Channel Analog Input (Safety-Related)

  • Safety Integrity Level: SIL 3 / AK6 / PLe

  • Input Range (Current): 0/4...20 mA (utilizing an external or internal shunt)

  • Input Range (Voltage): 0...5 V / 0...10 V DC

  • A/D Resolution: 12-Bit

  • Input Impedance: 100 kΩ

  • Measurement Scaling: 0 mV = 0 units | 5.5 V = 4095 units

  • Maximum Input Limits: 5.5 V (Voltage) / 22 mA (Current)

  • Galvanic Isolation: Safety-isolated channels for interference suppression

  • Form Factor: Compact module for HIMatrix rail-mounting

Configuration and Compatibility

The F6217/F 6217 (Part Number: F6217) is programmed and configured via the HIMA SILworX engineering tool. It is often utilized in distributed I/O architectures where analog process variables (pressure, temperature, flow) must be monitored with high reliability.

Frequently Asked Questions

How does the F 6217 handle current signals if it is a voltage-based input?The module measures voltage drops across a shunt resistor. When monitoring 0/4...20 mA loops, a shunt is applied to convert the current to a proportional voltage within the 0...5.5 V range.

Can the F 6217 be used in non-safety applications?While designed for SIL 3 safety loops, it can process standard control signals; however, its primary value lies in its diagnostic capabilities and failure-safe architecture.

Product Comparison

  • F 6217: 8-fold Analog Input, 12-bit resolution, versatile current/voltage support.

  • F 6214: 4-fold Analog Input, typically used for smaller-scale signal monitoring.

  • F 6221: High-density Digital Input module, used for discrete states rather than analog variables.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more
Mastering PLC Power Supply Architectures and Operating Voltages

Mastering PLC Power Supply Architectures and Operating Voltages

Selecting the correct operating voltage is a critical step in designing reliable industrial automation systems. Whether you are working with a compact PLC or a large-scale DCS, your power architecture dictates the system's longevity. In this guide, we explore the standard voltage ranges and power distribution strategies required to maintain stable factory automation operations.

Read more