GE DS200LRPAG1A Line Protection CardGE DS200LRPAG1A Line Protection CardGE DS200LRPAG1A Line Protection Card
GE DS200LRPAG1A Line Protection Card
GE DS200LRPAG1A Line Protection Card
GE DS200LRPAG1A Line Protection Card

GE DS200LRPAG1A Line Protection Card


Only 10 left - Selling fast

PRODUCT SKU : DS200LRPAG1A

PRODUCT TYPE : Line Protection Cards

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for electrical parameter monitoring and fault isolation in drive control systems, the GE DS200LRPAG1A (DS200LRPA Line Protection Card) provides direct physical/electrical execution of circuit breaker trip sequences upon detection of abnormal line conditions.

Hardware Specifications

Parameter Specification
Model DS200LRPAG1A
Brand GE (General Electric)
Origin USA
Operating Temp Standard industrial ambient
Primary Components Transformer, terminal strips, LED indicators, reset switch
Interface Vertical female cable connector, stab-on connectors

PLC/DCS Deterministic Network Integration

The DS200LRPAG1A performs real-time analysis of voltage, current, and frequency inputs to execute protective logic. Within the Drive Control system, the board maintains deterministic performance by comparing sampled input data against programmed thresholds. To ensure stability, the backplane bus communication velocity must be matched to the host controller requirements. Integration requires verification of firmware flash compatibility to ensure the protection algorithms—including ground fault and directional protection logic—are synchronized with the system's overall safety timing. Proper configuration prevents latency in trip signal delivery during fault events.

Frequently Asked Questions

Q: Can the onboard reset switch be utilized to clear trip signals while the power line is still in a fault state?

A: No. The reset switch should only be operated after the primary fault condition has been cleared and isolated. Attempting to reset the board while a fault persists will result in an immediate re-trip condition, as the protection logic will detect the violation upon re-initialization.

Q: How are the LED indicators used for diagnostic fault condition determination?

A: The LEDs provide status updates on internal board health and the operational state of the trip circuit. Refer to the specific GE system manual to map LED blink codes to fault categories, such as power supply failure, sensor input loss, or trip output status.

Field Installation Guidelines

  • Mounting: Utilize the factory-drilled holes in the board corners and along the edges for secure mounting via standoffs or screws. Ensure the board is electrically isolated from the cabinet chassis to prevent ground loops.
  • Sensor Termination: Connect line monitoring sensors to the designated terminal strips. Verify wire gauge and ensure screw terminals are tightened to specified torque to maintain low-resistance signal paths for current and voltage inputs.
  • Shielding: Terminate cable shields at the designated ground points to mitigate electromagnetic interference, which can cause erratic trip triggering.
  • Termination: Ensure the vertical female cable connector and stab-on connectors are fully seated. Loose connections on these interfaces can lead to signal degradation and false positive trip signals.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more