Skip to content

What are you looking for?


You may also like

ABB REJ603BB401NN3XE | Relion 605 Series | Self-Powered Feeder Protection RelayABB REJ603BB401NN3XE | Relion 605 Series | Self-Powered Feeder Protection RelayABB REJ603BB401NN3XE | Relion 605 Series | Self-Powered Feeder Protection Relay
ABB REJ603BB401NN3XE | Relion 605 Series | Self-Powered Feeder Protection Relay
ABB REJ603BB401NN3XE | Relion 605 Series | Self-Powered Feeder Protection Relay
ABB REJ603BB401NN3XE | Relion 605 Series | Self-Powered Feeder Protection Relay

ABB REJ603BB401NN3XE | Relion 605 Series | Self-Powered Feeder Protection Relay


Only 10 left - Selling fast

PRODUCT SKU : REJ603BB401NN3XE REJ603

PRODUCT TYPE : Feeder Protection Relay

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The ABB REJ603BB401NN3XE is a self-powered feeder protection relay developed for secondary distribution networks in both utility and industrial environments. As part of the Relion 605 series, it provides dependable protection without requiring auxiliary power, making it particularly suitable for unmanned substations and ring main units (RMU).

Key Features

  • Self-powered operation utilizing current transformers (CTs) for energy supply, eliminating external power sources

  • Protection functions including non-directional overcurrent protection (low/high set) and earth-fault protection (low/high set)

  • Selectable time characteristics with definite time and inverse time settings, supporting multiple standard and fuse curves

  • Fast startup response ensuring immediate protection availability

  • Compact design optimized for secondary distribution switchgear and RMU installations

Technical Specifications

  • Manufacturer ABB

  • Model REJ603BB401NN3XE

  • Series Relion 605

  • Product Type Self-Powered Feeder Protection Relay

  • Operation Mode Self-powered via CTs

  • Protection Functions Overcurrent (low/high set), Earth-fault (low/high set)

  • Time Characteristics Definite time, inverse time, fuse characteristics

  • Application Scope Secondary distribution networks, RMUs, unmanned substations

  • Startup Quick energization and protection response

Application Scenarios

  • Secondary distribution networks requiring reliable feeder protection without auxiliary power

  • Unmanned substations where compact and autonomous relays are essential

  • Ring main units (RMU) needing integrated feeder and earth-fault protection

FAQ

Q: Does the REJ603 require an external power supply?  A: No, it is fully self-powered using current transformers.

Q: What type of protection functions are included?  A: It supports non-directional overcurrent and earth-fault protection with selectable settings.

Q: Is the REJ603 suitable for RMU applications?  A: Yes, its compact design and self-powered operation make it ideal for RMUs.

Similar Model Comparison

  • REJ603BB401NN3XE: Self-powered, compact, optimized for RMU and secondary distribution

  • REF615: Advanced feeder protection with IEC 61850 communication support

  • REJ601: Basic self-powered feeder protection with limited functionality compared to REJ603

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more