Product Description

The GE Fanuc VersaMax IC200MDD844 Mixed Discrete I/O Module provides a balanced combination of inputs and outputs for industrial control systems. With 32 total points, including 16 inputs and 16 sourcing outputs, it offers fast response times and reliable signal processing. Designed for VersaMax systems, this module ensures efficient integration into automation environments requiring both input monitoring and output control.

Technical Specifications

  • Model / Part Number IC200MDD844

  • Manufacturer GE Fanuc Emerson

  • Product Line VersaMax

  • Product Type Discrete Mixed I/O Module

  • Weight 0.38 lbs (0.17 kg)

  • Total I/O Points 32

  • Inputs 16 discrete inputs

  • Outputs 16 discrete outputs (sourcing, positive logic)

  • Negative Logic Voltage 12 V

  • Response Time (On/Off) 0.5 ms

  • Backplane Voltage 5 VDC

  • Upgrade Requirement IC200MDD844C recommended for enhanced performance

Application Scenarios

  • Industrial automation systems requiring both input monitoring and output control in a single module

  • High-speed control applications needing fast response times

  • Compact installations where mixed I/O functionality reduces hardware footprint

FAQ

Q: How many I/O points does the IC200MDD844 provide?  A: It offers 32 points in total, with 16 inputs and 16 outputs.

Q: What type of outputs are supported?  A: Sourcing outputs with positive logic.

Q: What is the typical response time?  A: The module responds within 0.5 milliseconds.

Q: Is there an upgraded version available?  A: Yes, the IC200MDD844C is the recommended upgrade.

Comparison with Similar Models

  • IC200MDD844: 32-point mixed I/O, sourcing outputs, 0.5 ms response

  • IC200MDD841: High-speed counter module, 32 I/O points, 80 kHz pulse speed

  • IC200MDL240: 16-channel discrete input, 120 VAC operation

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more