Skip to content

What are you looking for?


You may also like

Honeywell 51199194-100 Flat Panel Touchscreen MonitorHoneywell 51199194-100 Flat Panel Touchscreen MonitorHoneywell 51199194-100 Flat Panel Touchscreen Monitor
Honeywell 51199194-100 Flat Panel Touchscreen Monitor
Honeywell 51199194-100 Flat Panel Touchscreen Monitor
Honeywell 51199194-100 Flat Panel Touchscreen Monitor

Honeywell 51199194-100 Flat Panel Touchscreen Monitor


Only 10 left - Selling fast

PRODUCT SKU : 51199194-100

PRODUCT TYPE : Touchscreen Monitors

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell 51199194-100, also cataloged as the 51199194-100 Flat Panel Display, operates as a dedicated hardware component for high-resolution visual monitoring and operator entry execution within Honeywell Z-Console Universal Station architectures. It processes video and touch input signals across a 20.1-inch LCD panel driving 1600 x 1200 resolution for real-time process graphics displaying DCS plant data.

Hardware Specifications

Parameter Specification
Model 51199194-100
Brand Honeywell
Origin USA
Dimensions 20.1-inch Diagonal Display
Operating Temp 0 to 50 deg C
Power Consumption 45 W Maximum (100-240 VAC, 50/60 Hz Input)
Display Resolution 1600 x 1200 pixels (UXGA)
Aspect Ratio 4:3
Optical Specs Brightness 250 cd/sq m, Contrast Ratio 1000:1
Response Time 16 ms (typical)
Viewing Angle 170 deg Horizontal, 170 deg Vertical
Touchscreen Interface Optional Resistive or Capacitive
System Compatibility Honeywell Z-Console Universal Station

FOUNDATION Fieldbus & HMI Signal Integration

The 51199194-100 display module renders high-density operator station schematics directly linked to process controllers tracking active FOUNDATION Fieldbus and Profibus PA segments. Internal shielding and industrial power supply filtering suppress high-frequency electrical noise and electro-magnetic interference originating from adjacent control room cabling. This ensures uncorrupted signal integrity across the video control board and prevents touch-controller drift or accidental activation during continuous industrial process monitoring.

Frequently Asked Questions

Q: Does replacing a legacy CRT monitor with the 51199194-100 require external AC-DC power converters?

A: No, the integrated power supply unit directly accepts universal line voltage ranging from 100 to 240 VAC at 50/60 Hz via standard internal power cabling.

Q: Can the 51199194-100 display be hot-swapped while the Z-Console operator station remains energized?

A: Video interface cable disengagement should occur only after isolating AC power to the display unit to avoid potential signal interface latch-up on the station controller board.

Field Installation Guidelines

  1. Isolate the AC main power feed before mounting the 20.1-inch flat panel into the Z-Console station cutout enclosure.
  2. Secure the display housing using specified mounting brackets, verifying metal-to-metal contact with the console frame for chassis grounding.
  3. Attach the video interface cable and optional touchscreen serial/USB controller cable, torquing thumb screws to prevent loose pin contact.
  4. Ensure adequate ventilation clearance around rear heat sinking vents to maintain internal operating temperatures within the 0 to 50 deg C range.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redefining Control System Design: The Evolution of Flexible Input/Output Modules (FIOM) in Industrial Automation

Redefining Control System Design: The Evolution of Flexible Input/Output Modules (FIOM) in Industrial Automation

Traditional industrial automation relies heavily on dedicated input-output (IO) modules. In a standard distributed control system (DCS) or programmable logic controller (PLC) setup, design engineers assign specific cards to distinct signal types. For instance, a traditional 16-channel digital input (DI) card exclusively processes digital signals. However, engineering projects frequently encounter last-minute changes in signal counts. Therefore, discovering a missing analog input (AI) channel late in the design phase forces engineers to purchase and install an entirely new, dedicated AI card. Consequently, this rigidity drives up hardware expenses, wastes cabinet space, and delays commissioning schedules.

Read more
Mastering VFD Braking Theory and Mechanical Brake Sequencing in Industrial Automation

Mastering VFD Braking Theory and Mechanical Brake Sequencing in Industrial Automation

In industrial automation, variable frequency drives (VFDs) regulate motor speed and torque across manufacturing plants and material handling systems. However, certain heavy-duty applications experience external loads that can rotate the motor shaft without an active command. For instance, gravity pulls loads downward in unanchored hoisting equipment. Therefore, engineers integrate mechanical brakes with VFD logic to maintain absolute safety and prevent structural damage or personnel injury during shutdowns.

Read more
Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Industrial automation engineers frequently encounter liquid level regulation challenges across diverse process plants. Traditional ON-OFF control mechanisms often disrupt system stability due to abrupt actuator switching. Therefore, upgrading to closed-loop architectures like proportional control yields smoother responses. In a typical PLC environment, such as Siemens TIA Portal, engineers utilize closed-loop feedback to minimize process errors without requiring full PID complexity.

Read more