Skip to content

What are you looking for?


You may also like

HIMA F 3421 8-Channel Digital Output Module Safety-Related Discrete UnitHIMA F 3421 8-Channel Digital Output Module Safety-Related Discrete UnitHIMA F 3421 8-Channel Digital Output Module Safety-Related Discrete Unit
HIMA F 3421 8-Channel Digital Output Module Safety-Related Discrete Unit
HIMA F 3421 8-Channel Digital Output Module Safety-Related Discrete Unit
HIMA F 3421 8-Channel Digital Output Module Safety-Related Discrete Unit

HIMA F 3421 8-Channel Digital Output Module Safety-Related Discrete Unit


Only 10 left - Selling fast

PRODUCT SKU : F3421

PRODUCT TYPE : Digital Output Module

PRODUCT VENDOR : Hima


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Technical Overview

The F 3421 (Part Number: F3421) is a high-performance digital output module engineered for the HIMA HIMatrix system, providing eight safety-related channels for industrial automation. This module is specifically designed to control safety-critical actuators, valves, and contactors in environments requiring SIL 3 compliance. It features advanced internal diagnostics and short-circuit protection, ensuring that the "safe state" is maintained even in the event of an external field fault.

Detailed Specifications

The following technical data outlines the electrical and mechanical performance of the F 3421 unit:

  • Output Capacity: 8 Safety-related digital channels

  • Nominal Voltage: 24 V DC

  • Output Current: Up to 0.5 A per channel (short-circuit proof)

  • Safety Integrity Level: Certified up to SIL 3 / PLe

  • Switching Logic: High-side switching with integrated wire-breakage monitoring

  • Galvanic Isolation: Safety isolation between the system bus and field level

  • Current Consumption: Approximately 50 mA at 24 V DC (internal electronics)

  • Dimensions: 2 cm x 18.8 cm x 12.8 cm

  • Net Weight: 0.18 kg

  • Manufacturing Origin: Germany

  • Protection Class: IP20-rated for cabinet installation

Functional Logic and Protection

The F 3421 is built to handle the rigors of emergency shutdown (ESD) and Fire and Gas (F&G) systems. Key functional features include:

  • Active Diagnostics: Continuous monitoring of the output stage for cross-circuit and external voltage interference.

  • Failure Response: In the event of a logic error or communication loss, the module automatically forces all outputs to a de-energized "safe" state.

  • Thermal Protection: Each channel is equipped with thermal shutdown capabilities to prevent module damage during overcurrent events.

Frequently Asked Questions

Does the F 3421 require external fusing for each channel?While the F3421 features electronic short-circuit protection, HIMA typically recommends external fusing for line protection depending on the cable cross-section and local safety regulations.

Can I parallel multiple outputs to increase the current load?Generally, safety modules like the F3421 are not designed for paralleling outputs to drive a single high-current load, as this can interfere with the diagnostic testing pulses used for safety monitoring.

Product Family Comparison

  • F3421: 8 digital outputs, 0.5 A per channel, standard HIMatrix form factor.

  • F3422: High-current variant often supporting up to 2 A per output for driving larger solenoids.

  • F3221: Digital input counterpart used for signal acquisition from field switches.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Main Components of a SCADA System in Industrial Automation

Main Components of a SCADA System in Industrial Automation

Discover the key components of a SCADA system and how sensors, RTUs, master units, and communication networks integrate to monitor and control industrial processes in real time.

Read more
Key Functions of a SCADA System in Industrial Automation

Key Functions of a SCADA System in Industrial Automation

Explore the four core functions of SCADA—data acquisition, communication, visualization, and control—and understand how this system powers industrial automation, process optimization, and remote supervision.

Read more
Instrumentation Earthing in Industrial Automation Systems

Instrumentation Earthing in Industrial Automation Systems

In industrial automation, earthing provides a safe, low-resistance path for electrical fault currents. It protects both equipment and personnel by diverting excessive current directly into the ground. Proper earthing is fundamental to PLC, DCS, and control system reliability, ensuring stable operation even under fault conditions.

Read more