Overview

The Allen-Bradley 1746-OA8 is a discrete AC output module designed for the SLC 500 series. It provides eight output channels organized into two groups, offering reliable switching for AC loads in industrial automation systems. With robust electrical ratings and fast response times, it is well-suited for general-purpose applications.

Technical Specifications

  • Manufacturer Allen-Bradley

  • Product Line SLC 500

  • Part Number 1746-OA8

  • Weight 0.20 kg (0.44 lbs)

  • Module Type Discrete AC Output Module

  • Number of Groups 2

  • Channels per Group 4

  • Nominal Output Voltage 120 / 240 VAC

  • Output Voltage Range 85–264 VAC

  • Backplane Current Consumption 185 mA at 5 VDC

  • ON Signal Delay (Resistive Load) 1 ms

  • OFF Signal Delay (Resistive Load) 11 ms

  • Continuous Current per Point 1.0 A at 30 °C (86 °F); 0.5 A at 60 °C (140 °F)

  • Continuous Current per Module 8.0 A at 30 °C (86 °F); 4.0 A at 60 °C (140 °F)

  • On-State Voltage Drop (Max) 1.5 V at 1.0 A

  • Surge Current per Point 10 A for 25 ms

  • Step Response 60 ms input, 2.5 ms output

Application Scenarios

  • General-purpose AC load control in manufacturing systems

  • Switching of lighting, heating, or motor loads

  • Integration into Allen-Bradley SLC 500 PLC systems for distributed control

FAQ

Q: How many outputs does the 1746-OA8 provide?  A: The module offers 8 outputs, divided into 2 groups of 4 channels each.

Q: What is the maximum current per channel?  A: 1.0 A at 30 °C and 0.5 A at 60 °C.

Q: Is this module suitable for inductive loads?  A: It is primarily designed for resistive loads, but can handle moderate inductive loads within rated specifications.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more