PRODUCT SKU : 4352B

PRODUCT TYPE : Communication Module

PRODUCT VENDOR : Triconex


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Description

The Triconex 4352B is a System Integration Communications Module (SI-TCM) for the Trident system. It provides high-speed data exchange between the safety system and external hosts, supporting multiple protocols to ensure seamless connectivity in safety-critical industrial networks.

Specifications

  • Manufacturer: Schneider Electric (Triconex).

  • Country of Origin: USA.

  • Model Number: 4352B.

  • Communication Ports: Two RS-485/RS-232 serial ports and one 10/100BaseT Ethernet port.

  • Protocols Supported: Modbus (RTU/ASCII), Modbus TCP, and TSAA.

  • Physical Weight: Approximately 0.9 kg (2.0 lbs).

  • Dimensions: 4.5" x 1.2" x 7.3" (114 mm x 30 mm x 185 mm).

  • Isolation: 500 VDC port-to-port and port-to-chassis.

  • Power Consumption: 4.0 Watts maximum.

  • Safety Rating: TUV approved for SIL3 integrated environments.

Features

  • Network Redundancy: Supports redundant communication links to ensure continuous data flow between the safety system and DCS.

  • Protocol Versatility: Compatible with industry-standard Modbus protocols for easy integration with third-party hardware.

  • Bi-Directional Communication: Allows for both data monitoring and authorized write-access for system configuration.

  • Hot-Swap Capability: Enables the module to be replaced while the system is under power without affecting the safety function.

  • Comprehensive Self-Diagnostics: Continuously monitors the health of communication ports and internal circuitry to detect faults.

  • Dedicated Status LEDs: Provides clear visual indicators for transmit/receive activity and module health on the front panel.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more
Architectural Selection and Scale Classification of PLC Systems in Industrial Automation

Architectural Selection and Scale Classification of PLC Systems in Industrial Automation

Selecting the correct control platform represents a foundational engineering decision in factory automation. System designers must carefully balance technical parameters against long-term operational requirements when implementing a Programmable Logic Controller (PLC). This article examines the critical evaluation metrics, physical scale classifications, and operational architectures of modern control systems.